Log and Trap Listing by Reason Code Overview
2-9
Log Reference for SBx3100 and iMAP Series Switches (SBx3112 Logs with Traps)
3. If multiple components are showing a temperature change, check the FM4 and replace
if necessary.
Alarms The following components are affected:
Component Status Alarm
• CFC200 Degraded Critical
• CFC200 Failed Critical
Note: In a simplex system, the CFC200 will be in a DEGRADED state, but will not go
out of service, since traffic would be affected.
2.1.10 POE Power Requested Exceeds Card Power Limit
Message To Be Supplied
Severity Minor
Explanation The GE24POE card cannot support the POE current configuration. You
must reconfigure the POE port power limits or add (if relevant) a
PoE PSU. This card alarm informs whether or not more power could be
requested than is available, even if no port is actually down. It is
a warning that there is a risk for insufficient power alarms on the
ports.
Action Perform the following:
1. Reconfigure the POE port power limits or add (if relevant) a PoE PSU.
Alarms The following components are affected:
Component Status Alarm
• GE24POE Degraded Minor
2.1.11 PSE Device Fault
Message To Be Supplied
Severity Major
Explanation A GE24POE card fault has been detected.
Action Perform the following:
1. Check the card and replace if necessary.
Alarms The following components are affected:
Component Status Alarm
• GE24POE Degraded Major