User guide
Overview Log and Trap Listing by Reason Code
Log Reference for SBx3100 and iMAP Series Switches (SBx3112 Logs with Traps)
2-4
Alarms The following components are affected:
Component Status Alarm
• CFC200 Degraded Critical
• CFC200 Failed Major
Note: For a simplex system, the alarm is critical since all data traffic could be dropped.
2.1.2 2.5V Power Failure
Message 2.5V Power Failure
Severity Critical
Explanation A problem has been detected with the 2.5v power output on the
CFC200, affecting data packet processing. The CFC200 card is prob-
ably defective.
Action Perform the following:
1. Replace the CFC card. If the problem is still not resolved, con-
tact Allied Telesis Support.
Alarms The following components are affected:
Component Status Alarm
• CFC200 Degraded Critical
• CFC200 Failed Major
Note: For a simplex system, the alarm is critical since all data traffic could be dropped.
2.1.3 3.3v Power Failed
Message Card Failure Raised
Severity Critical
Explanation A problem has been detected with the 3.3v power output on the CFC12
or CFC200 card. The card is probably defective.
Action Perform the following:
1. Replace the CFC card. If the problem is still not resolved, con-
tact Allied Telesis Support.
Alarms The following components are affected:
Component Status Alarm
• CFC12 Degraded Critical
• CFC200 Degraded Critical
• CFC200 Failed Major