User guide
Overview Log and Trap Listing by Reason Code
Log Reference for SBx3100 and iMAP Series Switches (iMAP Logs with Traps)
4-56
2.28 PMON005 - atnDs1DayUASThreshTrap
2.28.1 Not Applicable
Message Not Applicable
Severity Minor
Explanation The number of Unavailable Seconds condition exceeds the provisioned
threshold for the current 15-minute period.
Action Perform the following:
1. To B e S u p p l i e d .
Alarms The following components are affected:
Component Status Alarm
• None
2.29 PORT003 - Linkdown
2.29.1 CAS Thermal Shutdown
Message Port Fault Set
Severity Minor
Explanation The CAS (Card Access Switch) for this port has shutdown due to high
temperature. This could be the result of external voltage on the
line or could be due to a defective card that needs replacing.
Action Perform the following:
1. To B e S u p p l i e d
Alarms The following components are affected:
Component Status Alarm
• POTS Port Failed Minor
2.29.2 SLIC Thermal Shutdown
Message Port Fault Set
Severity Minor
Explanation The SLIC (Subscriber Line Interface Circuit) on the card for this
port has shutdown due to high temperature.
Action Perform the following:
1. Replace card.