2.14.34 Protocol Mismatch
Message Card Failure Raised
Severity Info
Explanation The PROTOCOL attribute on the POTS card (MGCP or SIP) doesn't match
the load running on the card (POTS24 or POTS24S).
Action Perform the following:
1. Change the prefload to match.
2. Or change the protocol attribute to match the load type.
Alarms The following components are affected:
Component Status Alarm
• POTS24 Failed Minor
2.14.35 Incompatible Load
Message Card Failure Raised
Severity Info
Explanation The Incompatible Load alarm is raised when the SM is running a load
that the CFC does not support. For example, this alarm is raised if
the CFC is running 9.0.x and the SM is running 7.x.x, 9.1.x or
10.0.x. This alarm is a failing alarm for the SM; the card cannot be
put into service.
Action Perform the following:
1. To B e S u p p l i e d
Alarms The following components are affected:
Component Status Alarm
• ADSL Failed Minor
• CES8 Failed Major
• EPON2 Failed Major
• FE10 Failed Minor
• FX10 Failed Minor
• GE Failed Major
• NTE8 Failed Major
• POTS24 Failed Minor