Log and Trap Listing by Reason Code Overview
4-27
Log Reference for SBx3100 and iMAP Series Switches (iMAP Logs with Traps)
2. Otherwise, verify power feed to shelf.
3. Replace AC power module.
4. Replace CFC card.
5. If the problem is still not resolved, contact Allied Telesis Technical Support.
Alarms The following components are affected:
Component Status Alarm
• CFC12 Degraded Minor
2.14.26 AC Power A Fan Failed
Message Card Failure Raised
Severity Minor
Explanation The power module controlling the AC power feed A has a fan failure.
The most likely problem is the AC power module itself.
Action Perform the following:
1. Replace the AC power module.
Alarms The following components are affected:
Component Status Alarm
• CFC12 Degraded Minor
2.14.27 AC Power B Fan Failed
Message Card Failure Raised
Severity Minor
Explanation The power module controlling the AC power feed B has a fan failure.
The most likely problem is the AC power module itself.
Action Perform the following:
1. Replace the AC power module.
Alarms The following components are affected:
Component Status Alarm
• CFC12 Degraded Minor
2.14.28 1.2v Power Failed
Message Card Failure Raised
Severity Critical