User guide
Log and Trap Listing by Reason Code Overview
4-19
Log Reference for SBx3100 and iMAP Series Switches (iMAP Logs with Traps)
4. Replace CFC card.
5. If the problem is still not resolved, contact Allied Telesis Technical Support.
Alarms The following components are affected:
Component Status Alarm
• CFC12 Degraded Minor
• CFC24 Degraded Minor
• CFC24 Degraded Minor
• CFC4 Degraded Minor
• CFC6 Degraded Minor
• CFC6 Degraded Minor
2.14.6 Power Fuse Failed
Message Card Failure Raised
Severity Minor
Explanation There is a defective power fuse on the control module card in the
specified slot.
Action Perform the following:
1. For simplex systems, replace the CFC card.
2. For duplex systems, swap activity, then replace the faulty card.
3. If the problem is still not resolved, contact Allied Telesis Technical Support.
Alarms The following components are affected:
Component Status Alarm
• CFC12 Degraded Minor
• CFC24 Degraded Minor
• CFC24 Degraded Minor
• CFC4 Degraded Minor
• CFC6 Degraded Minor
• CFC6 Degraded Minor
2.14.7 SB 2.5v Power Failed
Message Card Failure Raised
Severity Critical