User guide

Log and Trap Listing by Reason Code Overview
4-17
Log Reference for SBx3100 and iMAP Series Switches (iMAP Logs with Traps)
Component Status Alarm
ADSL Card Degraded Minor
SHDSL24 Degraded Minor
2.14.2 Power 18 Failed
Message Card Failure Raised
Severity Critical
Explanation A problem has been detected with the 1.8v power output on the CFC
switch board, affecting data packet processing. The CFC card is
probably defective.
Action Perform the following:
1. For simplex systems, replace the CFC card.
2. For duplex systems, swap activity, then replace the faulty card.
3. If the problem is still not resolved, contact Allied Telesis Technical Support.
Alarms The following components are affected:
Component Status Alarm
CFC4 Degraded Critical
CFC6 Degraded Critical
CFC6 Failed Minor
2.14.3 Power 25 Adj. Failed
Message Card Failure Raised
Severity Critical
Explanation A problem has been detected with the 2.5v power output on the CFC
switch board, affecting data packet processing. The CFC card is
probably defective.
Action Perform the following:
1. For simplex systems, replace the CFC card.
2. For duplex systems, swap activity, then replace the faulty card.
3. If the problem is still not resolved, contact Allied Telesis Technical Support
Alarms The following components are affected:
Component Status Alarm
CFC4 Degraded Critical
CFC6 Degraded Critical