AT-x210-24GT AT-x210-16GT AT-x210-9GT Gigabit Ethernet Switches 1 L/A MODE LINK / 3 5 7 9 11 13 15R 17 19 21 23R AT-x210-24GT ACT Gigabit Ethernet Switch SPEED / DUPLEX 15 L/A CONSOLE RESET MODE SPEED SELECT FAULT STANDBY 1 2 POWER RS-232 3 4 5 6 7 8 9 10 11 12 13 15R 14 16R 17 18 19 21 20 22 L/A 23R MODE 16 L/A 23 MODE 24 LINK / 15 ACT 16 23 DUPLEX 2 4 6 8 10 12 14 16R 18 20 22 CLASS 1 LASER PRODUCT 24R SFP 1 L/A MODE LINK / 3 5 7
Copyright © 2013 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesis, Inc.
Electrical Safety and Emissions Standards This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Translated Safety Statements Important: The indicates that a translation of the safety statement is available in a PDF document titled Translated Safety Statements posted on the Allied Telesis website at www.alliedtelesis.com.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Contents Preface............................................................................................................................................................... 1 Symbol Conventions .................................................................................................................................... 2 Contacting Allied Telesis..................................................................................
Contents iv
Figures Figure 1: AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT packaging.............................................................................. 8 Figure 2: AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Front Panels.......................................................................... 9 Figure 3: MODE LED Toggle button....................................................................................................................................
List of Figures vi
Tables Table 1. AT-x210-9GT POWER LED Functional Descriptions ..........................................................................................13 Table 2. AT-x210-16GT and AT-x210-24GT FAULT LED Functional Descriptions ..........................................................14 Table 3. AT-x210-16GT and AT-x210-24GT STANDBY LED Functional Descriptions .....................................................14 Table 4. AT-x210-9GT LINK/ACT and SPEED/DUPLEX LED Descriptions ...........................
List of Tables viii
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Preface This guide contains the installation instructions for the AT-x210-9GT, ATx210-16GT, and AT-x210-24GT Gigabit Ethernet Switches.
Symbol Conventions This document uses the following conventions: Note Notes provide additional information. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data. Warning Warnings inform you that performing or omitting a specific action may result in bodily injury. Warning Warnings inform you that an eye and skin hazard exists due to the presence of a Class 1 laser device.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Contacting Allied Telesis If you need assistance with this product, you may contact Allied Telesis technical support by going to the Support & Services section of the Allied Telesis web site at www.alliedtelesis.com/support.
4
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Chapter 1 Overview This chapter provides descriptions of the AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Gigabit Ethernet Switches and contains the following sections: “Features” on page 6 “Package Contents” on page 8 “Front and Back Panels” on page 9 “Management Software” on page 11 “Twisted Pair Ports” on page 12 “LEDs” on page 13 “Power Supply” on page 19 5
Chapter 1: Overview Features Here are the hardware features of the AT-x210-9GT, AT-x210-16GT and AT-x210-24GT Gigabit Ethernet Switches. Twisted Pair Ports SFP Slots Here are the basic features of the 10/100/1000 Mbps twisted-pair ports: 9, 16, or 24 ports per switch 10Base-T (IEEE 802.3i), 100Base-TX (IEEE 802.3u) and 1000Base-T (IEEE 802.3ab) compliant IEEE 802.3u Auto-Negotiation compliant Auto-MDI/MDIX 100 meters (328 feet) maximum operating distance IEEE 802.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide LEDs Installation Options Here is a brief description of the port LEDs: Power LED/Fault/Standby LEDs; refer to “POWER/FAULT/ STANDBY LEDs” on page 13. Speed and link/activity LEDs for the twisted pair ports; see “10Base-T/100Base-TX/1000 Base-T Link Activity LEDs” on page 15. Link/activity LEDs for the SFP slots; see “SFP LEDs” on page 17.
Chapter 1: Overview Package Contents Figure 1 illustrates the package contents for the AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Gigabit Ethernet Switches.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Front and Back Panels Figure 2 illustrates the front panels of the AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Gigabit Ethernet Switches.
Chapter 1: Overview Figure 3 illustrates the MODE LED toggle button on the front panel of the of the AT-x210-9GT and AT-x210-16GT Gigabit Ethernet Switches. This button changes front panel LEDs for SPEED, DUPLEX, or turns off LEDs.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Management Software The switches are shipped with the management software pre-installed. The software provides a command line interface and a GUI (Graphical User Interface) for in-band, over-the-network management.
Chapter 1: Overview Twisted Pair Ports The AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Layer 2 Gigabit Ethernet Switches feature 9, 16, and 24 twisted pair ports, respectively. All ports are 10Base-T, 100Base-TX, and 1000Base-T compliant. You can set the port speeds and duplex modes either automatically with IEEE 802.3u Auto-Negotiation or manually with the management software. The twisted pair ports feature 8-pin RJ-45 connectors. For the port pinouts, see “Connectors and Port Pinouts” on page 54.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide LEDs There are four types of LEDs on the AT-x210 switches: POWER/ FAULT/ STANDBY LEDs “POWER/FAULT/STANDBY LEDs” on page 13 “10Base-T/100Base-TX/1000 Base-T Link Activity LEDs” on page 15 “SFP LEDs” on page 17 The POWER LED reports the status of AC power and is located on the left side of the front panel of the AT-x210-9GT switch. See Figure 5.
Chapter 1: Overview Figure 6. FAULT LED on AT-x210-9GT L/A MODE LINK / ACT SPEED / DUPLEX L/A CONSOLE RESET MODE SPEED SELECT FAULT STANDBY 1 3 5 7 9 11 13 15R MODE L/A 2 4 6 8 10 12 14 16R MODE POWER RS-232 DUPLEX FAULT LED Table 2 describes the functions for the FAULT LED for the AT-x210-9GT and AT-x210-16GT switches. Table 2.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide 10Base-T/ 100Base-TX/1000 Base-T Link Activity LEDs The Link Activity (L/A) LEDs provide information about the 10Base-T/ 100Base-TX/1000Base-T ports. AT-x210-9GT Link/Activity and Speed LEDs The AT-x210-9GT switch indicates LINK/ACT (link/activity) and SPEED/ DUPLEX (speed/duplex) with two LEDs for each port. See Figure 8.
Chapter 1: Overview AT-x210-16GT Link/Activity LEDs The AT-x210-16GT switch has two LEDs per port on the front panel to indicate link, activity, duplex, and speed status. See Figure 9. L/A MODE LINK / ACT SPEED / DUPLEX L/A 1 3 5 7 9 11 13 15R MODE Speed and Link/Activity (LINK/ACT) L/A 2 4 6 8 10 12 14 16R MODE Figure 9.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide See Table 5 for a description for the AT-x210-16GT and AT-x210-24GT Link/Activity and Speed LEDs. Table 5. AT-x210-16GT and AT-x210-24GT LINK/ACT and SPEED/ DUPLEX LED Descriptions LED State Description Link/Activity (LINK/ACT) Off The port has not established a link with a network device, or the ecofriendly feature is enabled with the MODE LED button to turn off the front panel LEDs.
Chapter 1: Overview AT-x210-16GT Gigabit Ethernet Switch SFP 15 16 15 16 L/A LINK / CLASS 1 LASER PRODUCT ACT Speed and Link/Activity SFP LEDs Figure 12. AT-x210-16GT SFP Status LEDs The AT-x210-24GT SFP LEDs can be found on between the upper and lower SFP slots. See Figure 13. AT-x210-24GT Gigabit Ethernet Switch 15 L/A 16 LINK / 15 ACT 16 23 24 23 24 CLASS 1 LASER PRODUCT Speed and Link/Activity SFP LEDs SFP Figure 13.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Power Supply Each switch has an internal power supply with a single AC power supply socket on the back panel. To power the switch on or off, connect or disconnect the power cord provided with the switch. A power cord is supplied with the switch. Note For the power requirements, see the “Power Specifications” on page 53.
Chapter 1: Overview 20
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Chapter 2 Installation This chapter contains the following sections: “Reviewing Safety Precautions” on page 22 “Selecting a Site for the Switch” on page 24 “Cable Specifications” on page 25 “Unpacking the Switch” on page 26 “Installing the Switch on a Table or a Desktop” on page 27 “Installing the Switch in an Equipment Rack” on page 28 “Installing Optional SFP Transceivers” on page 35 “Cabling the Switc
Chapter 2: Installation Reviewing Safety Precautions Please review the following safety precautions before you begin to install the chassis or any of its components. Note The indicates that a translation of the safety statement is available in a PDF document titled Translated Safety Statements. Warning To prevent electric shock, do not remove the cover. No userserviceable parts inside. This unit contains hazardous voltages and should only be opened by a trained and qualified technician.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide All Countries: Install product in accordance with local and National Electrical Codes. E8 Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Chapter 2: Installation Selecting a Site for the Switch Observe the following requirements when choosing a site for your switch: 24 If you plan to install the switch in an equipment rack, verify that the rack is safely secured and will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack. If you are installing the switch on a table, verify that the table is level and secure.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Cable Specifications Table 7 contains the cable specifications for the twisted pair ports. Table 7. Twisted Pair Cabling and Distances Maximum Operating Distance Speed Type of Cable 10 Mbps Standard TIA/EIA 568-B-compliant Category 3 or better shielded or unshielded cabling with 100 ohm impedance and a frequency of 16 MHz.
Chapter 2: Installation Unpacking the Switch To unpack the switch, perform the following procedure: 1. Remove all of the components from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesis. 2. Place the switch on a level, secure surface. 3.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Installing the Switch on a Table or a Desktop You can install AT-x210-16GT and AT-x210-24GT switches on a desktop, or in a standard 19-inch equipment rack. To install AT-x210-16GT and ATx210-24GT switches in a rack, see “Installing the Switch in an Equipment Rack” on page 28. The AT-x210-9GT is rack mountable using an optional AT-x210-9GT rack mount kit (Part Number: 990-003904-00).
Chapter 2: Installation Installing the Switch in an Equipment Rack Note: These instructions show you how to install an AT-x210-9GT, AT-x210-16GT or AT-x210-24GT switch in an equipment rack. Rack mount kit brackets are included with AT-x210-16GT and AT-x210-24GT switches. The AT-x210-9GT switch is installed in a rack with the optional AT-x210-9GT rack mount kit (Part Number 990-003904-00). To install AT-x210-9GT, AT-x210-16GT or AT-x210-24GT switches in a 19-inch equipment rack, follow these steps: 1.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide 4. Mount an AT-x210-24GT switch in a 19-inch equipment rack using four equipment rack screws (not provided with the switch).
Chapter 2: Installation 5. For AT-x210-16GT Switches, attach the two rack mount brackets to the sides of the switch using the bracket screws that come with the unit. See the bracket position as shown in Figure 18 and Figure 19.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide 6. Mount an AT-x210-16GT switch in a 19-inch equipment rack using the provided spacer bracket mounts with four equipment rack screws (not provided with the switch), as shown in Figure 20.
Chapter 2: Installation 7. For AT-x210-9GT switches, first fit the rack mount handles to the brackets using the supplied M3x6mm pan head screws, as shown below in Figure 21. Figure 21. Fitting rack mount handles to the brackets for an AT-x210-9GT 8.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide 9. Next attach the cable tray brackets for AT-x210-9GT switches, as shown below in Figure 23. Figure 23. Attaching cable tray brackets for an AT-x210-9GT 10. Mount an AT-x210-9GT switch in a 19-inch equipment rack, as shown below in Figure 24, using the screws from the rubber feet after removing these screws, as shown earlier in Figure 15.
Chapter 2: Installation 11. Mount an AT-x210-9GT switch in a 19-inch equipment rack using the provided spacer bracket mounts with four equipment rack screws, as shown in Figure 25.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Installing Optional SFP Transceivers To install an SFP transceiver, perform the following procedure: Note The transceiver can be hot-swapped; you do not need to power off the switch to install a transceiver. However, always remove the cables before removing the transceiver. Note You should always install the transceiver before connecting the fiber optic cables to it. 1.
Chapter 2: Installation 4. For an AT-x210-24GT Switch, gently slide the transceiver into the SFP slot until it clicks into place, as shown in Figure 28. R R 1981 Figure 28. Inserting the SFP on an AT-x210-24GT 5. For an AT-x210-16GT Switch, gently slide the transceiver into the SFP slot until it clicks into place, as shown in Figure 29. 15R AT-x210 -1 Gigabit Ethernet 6GT Switch SFP 15 15 16 16 16R L/A LINK / ACT CLASS 1 LASER PRO DUCT Figure 29.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide 6. Verify that the handle on the transceiver is in the upright position, as shown in Figure 30. This secures the transceiver and prevents it from being dislodged from the slot. R R SFP Transceiver Handle 1983 Figure 30. Positioning the SFP Handle in the Upright Position 7. Eject SFP transceivers, as shown in Figure 31. First lower the SFP Transceiver Handle, then gently remove the SFP Transceiver.
Chapter 2: Installation Note SFP transceivers are dust sensitive. Always keep the plug in the optical bores when a fiber optic cable is not installed, or when storing the SFP. When you do remove the plug, keep it for future use. Note Unnecessary removal and insertion of an SFP can lead to premature failure. For information on the cable specifications of the SFP, consult the documentation shipped with the SFP. 9. Go to “Cabling the Switch” on page 39.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Cabling the Switch Observe the following guidelines when connecting twisted pair and fiber optic cables to the ports on the switch: The connector on the cable should fit snugly into the port on the switch. The tab on the connector should lock the connector into place. Because the twisted pair ports have auto-MDI/MDI-X, you may use straight-through twisted pair cable to connect any type of network device to the switch.
Chapter 2: Installation 40 The default speed setting for the ports is Auto-Negotiation. This setting is appropriate for ports connected to network devices that also support Auto-Negotiation. The default speed setting of Auto-Negotiation is not appropriate for ports connected to 10/100Base-TX network devices that do not support Auto-Negotiation and have fixed speeds.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Powering On the Switch To power on the AT-x210-24GT, AT-x210-16GT, or AT-x210-9GT switch, perform the following procedure: 1. Plug the power cord into the AC power connector, as shown in Figure 32 on the back of an AT-x210-16GT Switch. Power cable hook Power cable hook mount Figure 32. Lifting the AC Power Cable Hook on an AT-x210-16GT Switch 2.
Chapter 2: Installation Warning Power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. E3 Pluggable Equipment. The socket outlet shall be installed near the equipment and shall be easily accessible. E5 4. Verify that the POWER LED is green. If the LED is OFF, see Chapter 3, “Troubleshooting” on page 47. The switch is now powered on and ready for network operations.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Monitoring the Initialization Processes It takes about thirty seconds for the switch to initialize its management software programs and features, and load the default configuration. You may also monitor the bootup sequence by connecting a terminal or computer that has a terminal emulator program, to the Console port on the master switch. You will see the messages in Figure 34 here to Figure 36 on page 45. Bootloader 2.0.
Chapter 2: Installation Starting base/loopback... [ OK ] Starting base/sysctl... [ OK ] [ OK ] Starting base/reboot-stability... [ OK ] Starting base/autofs-card... [ OK ] Checking system reboot stability... [ OK ] Starting base/cron... [ OK ] Starting base/appmond... [ OK ] Starting hardware/openhpi... [ OK ] Starting hardware/timeout... [ OK ] Starting base/inet... [ OK ] Starting base/modules... [ OK ] Starting network/startup...
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Assigning Active Workload to HA processes: hsl, nsm, rmond, sflowd, vrrpd, irdpd, lacpd lldpd, loopprotd, mstpd, authd, epsrd, imi, imiproxyd Received event network.activated Loading default configuration Warning: flash:/default.cfg does not exist, loading factory defaults. .. done! Received event network.configured awplus login: Figure 36.
Chapter 2: Installation 46
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Chapter 3 Troubleshooting This chapter contains information on how to troubleshoot the switch if a problem occurs. Note For further assistance, please contact Allied Telesis Technical Support at www.alliedtelesis.com/support. Problem 1: The POWER LED on the front of the switch is off. Solutions: The unit is not receiving power.
Chapter 3: Troubleshooting cable: Category 3 or better for 10 Mbps operation and Category 5 and Category 5E for 100 and 1000 Mbps operation. Note A 1000Base connection may require five to ten seconds to establish a link. Problem 3: The LINK/ACT LED for an SFP transceiver is off. Solutions: The fiber optic port on the transceiver is unable to establish a link to a network device. Try the following: Verify that the network device connected to the fiber optic port is operating properly.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Problem 5: A port’s LINK/ACT LED is blinking. Solutions: The link between the port and the network device is intermittent. Try the following: Connect another network device with a different cable to the port. If the Link LED remains steady on, then the problem is with the original cable or the network device. If the problem is with an SFP transceiver, check that the transceiver is fully inserted in the slot.
Chapter 3: Troubleshooting 50
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Appendix A Technical Specifications 51
Appendix A: Technical Specifications Physical Specifications Dimensions Table 8. Chassis Dimensions Model W x D x H mm (in) AT-x210-9GT 263 mm x 179 mm x 38 mm (10.35 in x 7.05 in x 1.50 in) AT-x210-16GT 341 mm x 210 mm x 44 mm (13.42 in x 8.26 in x 1.73 in) AT-x210-24GT 440 mm x 210 mm x 44 mm (17.32 in x 8.26 in x 1.73 in) Weight Table 9. Chassis Weight Model W x D x H mm (in) AT-x210-9GT 1.4 kg (3.08 lbs) AT-x210-16GT 2.0 kg (4.41 lbs) AT-x210-24GT 2.7 kg (5.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Power Specifications Input Supply Voltage - 100-240 VAC, 50 - 60 Hz Table 11. Power Specifications AT-x210-9GT 12 W AT-x210-16GT 19 W AT-x210-24GT 28 W Electrical Safety and Electromagnetic Emissions Certifications Table 12.
Appendix A: Technical Specifications Connectors and Port Pinouts This section lists the connectors and connector pinouts. Figure 37 illustrates the pin layout for an RJ-45 connector and port. Figure 37. RJ-45 Connector and Port Pin Layout Table 13 lists the RJ-45 pin signals when a twisted pair port is operating in the MDI configuration. Table 13.
AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide Table 15 lists the RJ-45 connector pins and their signals when a 1000Base-TX port is operating at 1000 Mbps. Table 15.
Appendix A: Technical Specifications 56