Specifications

40 Port Interface Card
C613-03023-00 REV P
PIC Testing and Verification
Use the following methods to check that a PIC is installed and operating
correctly:
Verifying that the PIC has been recognised
Using a terminal to verify operation
Using the Test Facility to verify operation
Using an existing network to verify operation
Verifying that the PIC has been recognised
To verify that the switch or router has recognised the PIC, turn on the switch or
router, and enter the command:
show system
Figure 32 shows a typical output.
Figure 32: Example output from the show system command for a switch or router with PICs installed
Router System Status Time 16:30:13 Date 26-Nov-2007.
Board ID Bay Board Name Host Id Rev Serial number
--------------------------------------------------------------------------------
Base 182 AT-AR745 0 M2-0 50038295
PIC 299 1 AT-AR021(S)-03 PIC BRI(S) 0 P2-0 78615636
NSM 4PIC 87 AT-AR040-00 NSM 4PIC 0 M4-0 42098017
--------------------------------------------------------------------------------
Memory - DRAM :131072 kB FLASH : 16384 kB
--------------------------------------------------------------------------------
SysDescription
CentreCOM AT-AR745 version 2.9.1-11 27-Sep-2007
SysContact
SysLocation
SysName
SysDistName
SysUpTime
396 ( 00:00:03 )
Boot Image : 745_107.fbr size 894264 13-Dec-2006
DEVELOPMENT Build
Software Version: 2.9.1-11 27-Sep-2007
Release Version : 2.9.1-11 27-Sep-2007
Patch Installed : NONE
Territory : europe
Country : none
Help File : 700-291a.hlp
Main PSU : On Main Fan : On
RPS Monitor : Off
Configuration
Boot configuration file: boot.cfg
Current configuration: boot.cfg
Security Mode : Disabled