Specifications
48 Rapier Series Switch
C613-03020-00 REV N
This produces a display similar that shown in Figure 30.
Figure 30: Example output from the show test command
Important If a test fails, contact your authorised Allied Telesis distributor or
reseller.
10/100 switch ports A loopback plug is required to test 10/100MB switch ports. See “Loopback
Plugs for Testing Switch Interfaces” on page 30 for details of how to make a
loopback plug. To start testing on a switch port interface, use the command:
enable test int=portn
where n is the switch port number.
Gigabit switch ports To test a Gigabit switch port, connect two ports using a crossover or straight-
through cable, and enable testing on all ports, using the command:
enable test int=all
NSM and PIC
interfaces
For information about testing NSM interfaces, see the Network Service Module
Hardware Reference. For information about testing PIC interfaces, see the Port
Interface Card Hardware Reference. You can download these documents from
www.alliedtelesis.com/support/software.
Board ID Bay Board Name Host Id Rev Serial number
----------------------------------------------------------------------------
Base 114 AT-RP24i Rapier 24i 0 M1-0 6845822
Uplink 88 1 AT-A35SX/SC-00 P1-0 14269019
Duration Details
Interface State Result Type (minutes) Data( %OK ) Control
----------------------------------------------------------------------------
port1 no test - - - - - -
port2 no test - - - - - -
port3 no test - - - - - -
port4 no test - - - - - -
port5 no test - - - - - -
port6 no test - - - - - -
port7 no test - - - - - -
.
.
.
port23 no test - - - - - -
port24 no test - - - - - -
port26 no test - - - - - -
asyn0 no test - - - - - -
----------------------------------------------------------------------------