Specifications

26 Rapier Series Switch
C613-03020-00 REV N
Record the serial number and revision of the base unit and PAC for later
reference. If you have any difficulty with the PAC at any time, contact your
authorised Allied Telesis distributor or reseller and quote the serial numbers
and revision of both the base unit and the PAC.
If there is no entry for the PAC then the switch’s boot process has not correctly
detected the card’s presence. The most likely cause is that there is no PAC
installed, or the PAC is not correctly installed in the switch. Contact your
authorised Allied Telesis distributor or reseller.
Figure 23: Example output from the show system command for a Rapier switch with an AT-AR061 ECPAC installed
Next, check the status of the PAC by displaying a log of PAC events, using the
command:
show log
For more information about this command, see the Logging Facility chapter of
the Rapier Series Switch AlliedWare
®
Operating System Software Reference. A
typical display is shown in Figure 24.
Figure 24: Example output from the SHOW LOG command for a Rapier switch with an AT-AR061 ECPAC card installed
If the log shows that the PAC was not recognised or could not be initialised,
contact your authorised Allied Telesis distributor or reseller.
Testing functionality When the PAC is operating, you can test its functionality by using the Test
Facility software or by configuring a module to use it. For more information
about the Test Facility, see the Test Facility chapter of the Rapier Series Switch
AlliedWare
®
Operating System Software Reference. For more information about
configuring interfaces, see the Compression and Encryption Services chapter of
the Rapier Series Switch AlliedWare
®
Operating System Software Reference.
Switch System Status Time 00:23:04 Date
15-Jun-2001.
Board ID Bay Board Name Rev Serial number
--------------------------------------------------------------------------
Base 86 AT-RP24 Rapier 24 M2-1 46690596
PAC 153 AR061 ECPAC P1-16 6844578
--------------------------------------------------------------------------
Memory - DRAM : 32768 kB FLASH : 6144 kB
--------------------------------------------------------------------------
SysDescription
Allied Telesyn AT-RP24 version 2.2.2-00 18-May-2001
.
.
.
Date/Time S Mod Type SType Message
-------------------------------------------------------------------------------
15 00:05:50 4 ENCO ENCO PAC 7751 Found. Initialisation started
15 00:05:50 4 ENCO ENCO PAC 7751 Initialisation Successful
15 00:05:50 7 SYS REST NORM Switch startup, ver 2.2.2-00, 18-May-2001, Clock
Log: 00:04:40 on 15-Jun-2001
15 00:05:53 3 USER USER 00011 manager login failed on port0
15 00:05:58 3 USER USER LON manager login on port0
15 00:05:59 3 CH MSG WARN No patches found
-------------------------------------------------------------------------------