Specifications

Hardware Reference 13
C613-03020-00 REV N
Rapier 48w and Rapier 48w-B
The Rapier 48w and 48w-B have the same features, but take different NSM
model versions. See the section “Network Service Modules” on page 21 for the
list of compatible NSMs.
The Rapier 48w is a DC model only, while the 48w-B is available in both AC
and DC models. You can install the Rapier 48w and 48w-B DC models as
Network Equipment Building System (NEBS) compliant. The AC model has
not been tested for NEBS compliance.
48 x 10BASE-T/100BASE-TX ports (RJ-45 connectors)
Two 1000BASE SFP ports
Two asynchronous serial console ports with DB9 connectors
One Network Service Module bay
Auto-negotiating Layer 3 managed switch
Enhanced switching core
Replaceable air filters and fan-only modules (FOMs) for NEBS applications
Figure 16: Front panel of the Rapier 48w and 48w-B
Figure 17: Rear panel of DC models
Figure 18: Rear panel of AC models
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
FAN 2FAN 1
STATUS
FAULT
POWER
SWAP
IN
USE
HOT
SWAP
NSM
RESET
NSM
12345678910111213
14
15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
32
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49
50
Rapier 48w L3
Fast Ethernet
Switch
PORTS 49-50
INSTALLED
FAULT
ACT
SFP
1000M LINK
L/A
D/C
L/A
FULL DUP HALF DUP COLACTLINK 100M ACT
LINK 10M
PORTS 1-48
ASYN1
ASYN0
WARNING
This unit might have more
than one power input. To
reduce the risk of electric
shock, disconnect all power
inputs before servicing unit.
FOR CENTRALIZED DC
POWER CONNECTION,
INSTALL ONLY IN A
RESTRICTED AREA.
40-60VDC
4.5A MAX
DUAL INPUTS
WARNING
This unit might have more
than one power input. To
reduce the risk of electric
shock, disconnect all power
inputs before servicing unit.
FOR CENTRALIZED DC
POWER CONNECTION,
INSTALL ONLY IN A
RESTRICTED AREA.
40-60VDC
4.5A MAX
DUAL INPUTS