user manual
AT-MC606 VDSL Network Extender Installation Guide
31
Selecting a Site for the AT-MC606 VDSL Network Extender
Observe the following requirements when choosing a site for your 
AT-MC606 VDSL Network Extender:
 If you plan to install a AT-MC606 VDSL Network Extender into an AT-
MCR12 rackmount chassis and equipment rack, check to be sure that 
the rack is safely secured and that it will not tip over. Devices in a rack 
should be installed starting at the bottom, with the heavier devices near 
the bottom of the rack.
 The AT-MC606 VDSL Network Extender may be wall mounted either 
on a DINRAIL using a DINRAIL bracket or using an AT-WLMT bracket. 
Both brackets are provide separately. Select a place on the wall that 
provides the best cabling and power access.
Note
Both the DINRAIL bracket and the AT-WLMT wall mount bracket are 
sold separately. Contact your Allied Telesis Sales representative to 
purchase these items.
 If you are installing the AT-MC606 VDSL Network Extender on a table, 
be sure that the table is level and secure.
 The power outlet for the AT-MC606 VDSL Network Extender should be 
located near the unit and should be easily accessible.
 The site should provide for easy access to the ports on the front of the 
AT-MC606 VDSL Network Extender. This makes it easy for you to 
connect and disconnect cables, as well as view the LEDs.
 To allow proper cooling of the AT-MC606 VDSL Network Extender, air 
flow around the unit and through its vents on the side should not be 
restricted.
 Do not place objects on top of the AT-MC606 VDSL Network Extender.
 Do not expose the AT-MC606 VDSL Network Extender to moisture or 
water. 
 Make sure that the site is a dust-free environment.
 You should use dedicated power circuits or power conditioners to 
supply reliable electrical power to the AT-MC606 VDSL Network 
Extender.










