MWS Series Access Point Installation Guide
25
Cable Specifications
To connect the MWS series access point to your LAN, you must provide
cables. Here are cable requirements and options.
Cable
Requirements
The cable requirements for the LAN port are listed in Table 5.
Maximum
Distance
The LAN port has a maximum operating distance of 100 meters (328 feet).
Table 5. Twisted Pair Cable for the LAN Port
Cable Type
10Mbps 100Mbps 1000Mbps
PoE+ PoE+ PoE+
Standard TIA/EIA 568-A-compliant
Category 5 shielded or unshielded
cabling with 100 ohm impedance and
100 MHz frequency.
Yes Yes No
Standard TIA/EIA 568-B-compliant
Enhanced Category 5 (Cat 5e) shielded
or unshielded cabling with 100 ohm
impedance and 100 MHz frequency.
Yes Yes Yes
Standard TIA/EIA 568-B-compliant
Category 6 or 6a shielded cabling.
Yes Yes Yes