4. Start a local management session on the unit by performing the next
procedure.
Starting a Local
Management
Session
The following procedure describes how to connect an RJ-45 cable to an
x600 switch. For information about how to log onto the AlliedPlus
TM
Operating System Software, see the AlliedWare Plus
TM
Operating System
Software Reference Guide.
To start a local management session on the unit, perform the following
procedure:
1. Connect the RJ-45 end of the management cable included with the
x600 switch to the Terminal Port on the front panel of the switch, as
shown in Figure 30.
Figure 30. Connecting the Management Cable to the RJ-45 Terminal Port
on the Switch
2. Connect the other end of the cable to an RS-232 port on a terminal or
a personal computer with a terminal emulation program.
3. Configure the terminal or terminal emulation program as follows:
Baud rate: Default is 9600 bps (Range is 9600 to 115200 bps)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.