System information

22
How to see system information
The switch monitors the environmental status of the switch and its power supplies and fan. To
display this information, enter User Exec or Privileged Exec mode and enter the command:
awplus#show system environment
The output looks like the following figure. This device has a power supply unit in the first
PSU bay and a fan in the second PSU bay.
The switch’s serial number is displayed in the output of the show system command, but for
convenience, you can also display it by itself. To do this, enter User Exec or Privileged Exec
mode and enter the command:
awplus#show system serialnumber
The output looks like this:
Viewing temperature, voltage, and fan status
Environment Monitoring Status
Overall Status: Normal
Resource ID: 1 Name: PSU bay 1
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present 1 - - Ok
2 PSU Overtemp 0 - - Ok
3 PSU Fan Fail 0 - - Ok
4 PSU Power Good 1 - - Ok
Resource ID: 2 Name: PSU bay 2
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present 1 - - Ok
2 PSU Overtemp 0 - - Ok
3 PSU Fan Fail 0 - - Ok
4 PSU Power Good 0 - - Ok
Resource ID: 3 Name: x900-24XT
ID Sensor (Units) Reading Low Limit High Limit Status
1 Voltage: 2.5V (Volts) 2.578 2.344 2.865 Ok
2 Voltage: 1.65V (Volts) 1.629 1.488 1.816 Ok
3 Voltage: 3.3V (Volts) 3.352 2.973 3.627 Ok
4 Voltage: 1.8V (Volts) 1.797 1.615 1.979 Ok
5 Voltage: 12V (Volts) 11.938 10.813 13.188 Ok
6 Temp: Ambient (Degrees C) 25 -127 55 Ok
7 Temp: Sensor chip (Degrees C) 45 -127 75 Ok
8 Temp: Internal (Degrees C) 38 -127 75 Ok
Viewing the serial number
P1FY7502C