Appendix A: Technical Specifications
108
Table 19 lists the fiber optic port specifications for the AT-StackOP/9.0
transceiver.
Transmitter
Wavelength 850 nm
Output Optical Power -7.3 dBm min.
Receiver
Wavelength 850 nm
Maximum Sensitivity -9.9 dBm
Maximum Input Power -1 dBm
Table 19. Fiber Optic Port Specifications for the AT-StackOP/9.0
Transceiver
General
Maximum Distances 9 km
Fiber Optic Cable 9/125 µm (core/cladding) single-
mode fiber optic cable
Transmitter
Wavelength 1310 nm
Output Optical Power -8.2 dBm min.
+0.5 dBm max.
Receiver
Wavelength 1310 nm
Maximum Sensitivity -14.4 dBm
Maximum Input Power 0.5 dBm
Table 18. Fiber Optic Port Specifications for the AT-StackOP/0.3 Module