Owner's manual

Page 200
Allied Telesis
AT-8000GS Command Line Interface Users Guide
7/g3 Copper
Temp – Internally measured transceiver temperature.
Voltage - Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured TX output power.
Input Power – Measured RX received power.
Tx Fault – Transmitter fault
LOS – Loss of signal
console>
show fiber-ports optical-transceiver detailed
Power
Port Temp Voltage Current Output Input TX LOS
[C] [Volt] [mA] [mWatt] [mWatt] Fault
------ ------ ------- ------- ------- ----- ------ -----
7/g1 48 5.15 50 1.789 1.789 No No
7/g2 43 5.15 10 1.789 1.789 No No
7/g3 Copper
Temp – Internally measured transceiver temperature.
Voltage - Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured TX output power in milliWatts
Input Power – Measured RX received power milliWatts
Tx Fault – Transmitter fault
LOS – Loss of signal