Specifications

6 AT-8800 Series Switch
C613-03066-00 REV D
Dimensions
Mounting System
•1U rack mounting
Environmental Conditions
Operating temperature range: 0 to 50º C (32 to 122º F)
Storage temperature range: -20 to 60º C (-4 to 140º F)
Relative humidity range: 5 to 95% non-condensing
Regulatory Standards
AC models
AS/NZS3260
CNS 13438 Class A
•BSMI
VCCI Class A
EMC: EN55022 class A, FCC class A, and VCCI class I
Immunity testing to EN55024: EN61000-3 levels 2 (Harmonics), and 3
(Flicker). EN61000-4 levels 2 (ESD), 3 (susceptibility), 4 (fast transients),
5 (power surge), 6 (RF immunity), and 11 (Voltage dips and sags).
Safety: UL60950, CAN/CSA-C22.2 NO. 60950-00, EN60950, ACA TS001
Certification: UL, cUL, TUV
LEDs
•Port and System status LEDs
For a complete list of LEDs and their functions, see “LEDs and What
They Mean” on page 26.
Power Supply Unit
AC models
Universal 100/240 VAC 50/60 Hz input
•Redundant DC Power connection
Table 1: Dimensions for AT-8824 and AT-8848.
AT-8824 and AT-8848
Height 1U - 44 mm (plus 5.5 mm if the rubber feet are used).
Width 440 mm (excluding rack-mounting brackets).
Depth 350 mm.
Weight Not more than 6 kg excluding power cord.