Specifications
16 AT-8800 Series Switch
C613-03066-00 REV D
PASS: RAM test, 65536k bytes found.
The RAM test passed, and the indicated amount of memory was found
and will be used by the switch.
ERROR: RAM test 5. Error address = 00345678.
A RAM test failed, at the given address. In the example, it was the fifth
test run. The RAM test repeats until it passes, so a number of messages
like this may appear. This fault means that the memory system is faulty.
If the fault continues, contact your authorised Allied Telesyn distributor
or reseller immediately.
INFO: BBR tests beginning.
The BBR battery tests are about to begin.
PASS: BBR test, 128k bytes found.
The BBR size/location test passed, with the indicated amount of BBR
found.
FAIL: BBR test. Error address = 12345678.
The BBR size/location test failed at the given location. The test at this
location failed, indicating the end of memory, but a valid location was
discovered in the 255 long words following this location. The BBR
system will need to be replaced. Contact your Authorised Allied
Telesyn distributor or reseller.
FAIL: BBR test, only 16k bytes found.
The BBR size/location test completed, but only the displayed amount
of memory was found. This amount is less than the minimum required
to run the switch software.
INFO: Self tests complete.
The start-up tests have finished.
INFO: Downloading switch software.
The process of downloading the switch software and vector table from
ROM is about to begin.
ERROR: Code load retried.
FAIL: Code load failed.
The load of the code from ROM to RAM failed. The load is retried a
number of times. Each time a failure occurs, the ERROR message is
displayed. If the maximum number of attempts is reached, the FAIL
message is displayed.
INFO: Initial download successful.
The start-up tests and download are complete, and the switch software
is about to be started.
INFO: Executing configuration script <script-name>
The configuration commands stored in <script-name> are being
executed. If an error is found in the script, one or more ERROR
messages will be displayed.
INFO: Switch startup complete.
The start-up process is complete and the switch will now perform basic
switching operations. Further configuration will be necessary if you wish to
access the switch’s full layer 3 switching capabilities. See your AT-8800 Series
Software Reference for detailed information on configuring the switch.