Operation Manual

Phone
SIP Software Release 6-0-0
J613-M0524-00
75
toff a time interval expressed in msec within 0,5000 range
rfreq a frequency expressed in Hz within 16-70 range
tfreq a frequency expressed in Hz within 20,1000 range
gain expressed in dB within ---12,+12 range with 3 dB steps.
impedance is the name of the interface equivalent circuit. The possible value are
600R, 600C, 900C, CPLX1 and CPLX2.
blen input circular buffer length in milliseconds within 0,500 range
bthr input circular buffer threshold in milliseconds within 0, blen range
dtout timeout in seconds within 1, 255 range
lecframe number of frames in 0, 63 range
digit can be a phone keypad valid digit, i.e. 0-9 * and #.
duration is expressed in seconds in 0,60 range.
Description
This command sets different parameters for FXS port configuration.
A signal/tone cadence can be specified with a series of on and of time
interval. This waveform is than repeated as long as the signal or tone is
active.
RING and RINGFREQ set the ring signal, its cadence and its frequency
when there is an incoming call. The default values are (1000, 4000) and
25 respectively.
TRING and TRINGFREQ set the ring tone cadence and its frequency
when the called party phone is ringing. The default values are (1000,
4000) and 425 respectively.
TDIAL and TDIALFREQ set the dial tone cadence and its frequency
when the system is ready to collect the digits for making a call. The
default values are (1000, 0) and 425 respectively.
TBUSY and TBUSYFREQ set the busy tone cadence and its frequency
when the called party phone is busy. The default values are (500, 500)
and 425 respectively.
TDISC and TDISCFREQ set the disconnect tone cadence and its
frequency when the called party phone or the VoIP server cannot be
reached. The default values are (500, 500) and 425 respectively.
TWAIT and TWAITFREQ set the busy tone cadence and its frequency