Stacking Module AT-MCF2000S Installation Guide PN 613-000708 Rev A
Copyright © 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesis, Inc.
Electrical Safety and Emission Compliance Statement Standards: This product meets the following standards when installed in compliant host equipment. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Electrical Safety and Emission Compliance Statement European Union Restrictions of Use of Certain Hazardous Substances (RoHS) in Electrical and Electronic Equipment This Allied Telesis RoHS-compliant product conforms to the European Union Restriction of the Use of Certain Hazardous Substances (RoHS) in Electrical and Electronic Equipment. Allied Telesis ensures RoHS conformance by requiring supplier Declarations of Conformity, monitoring incoming materials, and maintaining Manufacturing process controls.
Contents Preface .........................................................................................7 Document Conventions .................................................................8 Where to Find Web-based Guides ................................................9 Contacting Allied Telesis .............................................................10 Online Support ....................................................................10 Email and Telephone Support...............................
Contents 6
Preface This guide provides a description of the AT-MCF2000S Stacking Module and instructions on how to install it.
Preface Document Conventions This document uses the following conventions: Note Notes provide additional information. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data. Warning Warnings inform you that performing or omitting a specific action may result in bodily injury.
AT-MCF2000S Stacking Module Installation Guide Where to Find Web-based Guides The installation and user guides for all Allied Telesis products are available in portable document format (PDF) on our web site at www.alliedtelesis.com. You can view the documents online or download them onto a local workstation or server.
Preface Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales or corporate information. Online Support You can request technical support online by accessing the Allied Telesis Knowledge Base: www.alliedtelesis.com\support. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
AT-MCF2000S Stacking Module Installation Guide Sales or Corporate Information You can contact Allied Telesis for sales or corporate information on our web site: www.alliedtelesis.com. Select your country from the list displayed on the website. Then select the appropriate menu tab.
Preface 12
Chapter 1 Installation This chapter describes how to install the stacking module.
Chapter 1: Installation Overview The AT-MCF2000S Module is a stacking module for the AT-MCF2000 Media Converter Series. See Figure 1. AT-M C F200 0S STAC K1 LINK PORT ACT ACTIV ITY STAC K2 CHAS SIS ID 1264 Figure 1. AT-MCF2000S Stacking Module Features The stacking module contains the following features: 14 There are two RJ-45 Fast Ethernet connections on the front of the module. The port on the left is labeled STACK 1 and the port on the right is labeled STACK 2.
AT-MCF2000S Stacking Module Installation Guide An LED display shows the chassis ID of the stacking module. A set of DIP switches located on the top of the module permits you to set the chassis ID. For the stacking module, the range of chassis ID is from 1 to 30. Verifying the Package Contents Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesis sales representative for assistance.
Chapter 1: Installation Reviewing Safety Guidelines Review the following safety guidelines affecting the host equipment before installing the module. Warning: Power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. E3 Pluggable Equipment. The socket outlet shall be installed near the equipment and shall be easily accessible. E5 Caution: Air vents must not be blocked and must have free access to the room ambient air for cooling.
AT-MCF2000S Stacking Module Installation Guide Installing the AT-MCF2000S Stacking Module This section provides a description of how to install the stacking module. Before you begin to install the module in the chassis, review the following information: For information and guidelines on the stacking feature of the AT-MCF2000 Media Converter Series, refer to the AT-MCF2000M Management Module Installation Guide and the AT-S85 and AT-S97 Management Software Command Line Interface User’s Guide.
Chapter 1: Installation To install the AT-MCF2000S Stacking Module, perform the following procedure: 1. Remove the module from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesis. 2. Remove the blank panel from the management slot on the chassis by loosening the two captive screws on the panel with a cross-head screwdriver. See Figure 2.
AT-MCF2000S Stacking Module Installation Guide Note Do not remove the blank panel from the chassis until you are ready to install a module. An open slot allows dust to enter the unit and hinders the ability of the chassis to maintain proper airflow and cooling. 3. Remove the tape from the DIP switch. 4. Set the chassis ID of the stacking module. Use the tip of a ballpoint pen to change the setting of the DIP switch. See Figure 3 on page 20. The chassis ID can be from 1 through 30.
6 OF F 1 ON Chapter 1: Installation AT-M CF2 000S STAC K1 LINK POR ACT T ACT IVITY STAC K2 CHAS SIS ID 1265 Figure 3. Changing the DIP switch 5. Align the edges of the module with the guides in the slot and carefully slide the module into the chassis until it is flush with the back panel of the chassis. See Figure 4 on page 21. You may need to exert light pressure to seat the module on the connector on the back panel of the chassis. Caution Do not force the module into place.
AT-MCF2000S Stacking Module Installation Guide AT-M C F200 0S STAC K 1 LINK PORT ACT ACTIV ITY STAC K2 CHAS SIS ID 1258 Figure 4. Installing the AT-MCF2000S Stacking Module 6. Secure the module to the chassis by the tightening the two captive screws with a cross-head screwdriver. See Figure 5 on page 22.
Chapter 1: Installation AT-M CF2 000S STAC K1 LINK PORT AC ACT TIVITY STAC K 2 CHAS SIS ID AT-M CF 2KFA N STAT US NORM FAUL AL T 1256 Figure 5. Securing the AT-MCF2000S Stacking Module 7. Connect the cables from the STACK ports on the other units in the stack to the STACK 1 and STACK 2 ports. See Figure 6 on page 22. AT-M C F200 0S STAC K1 LINK PORT ACT ACTIV ITY STAC K 2 CHAS SIS ID AT-M CF 2KFA N STAT US NORM FAUL AL T 1257 Figure 6.
AT-MCF2000S Stacking Module Installation Guide If this is the last chassis in the stack, you can connect the stacking cable to either port. For cabling guidelines, see the next section. Cabling a Media Converter Stack To create a stack of media converters, you daisy-chain the units with the Stack ports. The Stack port on the AT-MCF2000M Management Module must be connected to the STACK 1 or STACK 2 port on the AT-MCF2000S Stacking Module in the next chassis.
Chapter 1: Installation AT-MCF2000M LINK ACT 1000 LINK ACT 10/100 LINK ACT FDX HDX COL PORT ACTIVITY STACK MANAGEMENT AT-MCF2000S STACK 1 TERMINAL BOOT RESET RDY LINK ACT STACK 2 PORT ACTIVITY FAULT CHASSIS ID SYSTEM 0 ID MASTER SD POWER 31 10/100/1000BASE-T AT-MCF2000M LINK RS-232 ACT 1000 LINK BUSY RDY ACT 10/100 LINK ACT FDX HDX COL PORT ACTIVITY STACK MANAGEMENT AT-MCF2000S STACK 1 TERMINAL BOOT RESET RDY FAULT LINK ACT PORT ACTIVITY STACK 2 CHASSIS ID
AT-MCF2000S Stacking Module Installation Guide AT-MCF2000S AT-MCF2000S STACK 1 LINK ACT STACK 2 STACK 1 CHASSIS ID PORT ACTIVITY AT-MCF2000S LINK ACT STACK 2 CHASSIS ID PORT ACTIVITY AT-MCF2000S STACK 1 LINK ACT STACK 2 STACK 1 CHASSIS ID PORT ACTIVITY AT-MCF2000S LINK ACT STACK 2 CHASSIS ID PORT ACTIVITY AT-MCF2000S STACK 1 LINK ACT STACK 2 STACK 1 CHASSIS ID PORT ACTIVITY AT-MCF2000S LINK ACT STACK 2 CHASSIS ID PORT ACTIVITY AT-MCF2000S STACK 1 LINK ACT PORT ACT
Chapter 1: Installation 3. If this is the last chassis in the stack without a redundant management module, connect the stacking cable to either STACK 1 or STACK 2 port. For more cabling guidelines, see the AT-MCF2000 Multi-channel Media Converter Chassis Installation Guide. Note If this is the initial installation of the chassis, see the AT-MCF2000 Multi-channel Media Converter Chassis Installation Guide for instructions on how to install the remaining modules in the chassis.
AT-MCF2000S Stacking Module Installation Guide AT-MCF2000S Stacking Module LED The AT-MCF2000S Stacking Module has two ports labeled STACK 1 and STACK 2. See Figure 1 on page 14. Each Stack port has one LED labeled L/A for Link/Activity. The states of the LED are defined in Table 1. Table 1. LED State Description Off The port has not established a link with a port on another stacking module. Steady green The port has established a link with a port on another stacking module.
Chapter 1: Installation Removing the AT-MCF2000S Stacking Module To remove the AT-MCF2000S Stacking Module, perform the following procedure: 1. Remove all cables from ports on the module. 2. Using a cross-head screwdriver, loosen the two captive screws that secure the module to the chassis. 3. Slide the module from the chassis. Caution The AT-MCF2000S Stacking Module is sensitive to and can be damaged by electrostatic discharge.
AT-MCF2000S Stacking Module Installation Guide Troubleshooting If the STACK ports on the module are unable to establish a link, try the following: Verify the module is fully seated in the management slot in the AT-MCF2000 Chassis. Verify the chassis is powered on and operating properly. Verify you are using Standard TIA/EIA 568-A-compliant Category 5 or TIA/EIA 568-B-compliant Enhanced Category 5 (Cat 5E) shielded or unshielded cabling. Verify the cables are firmly secured to the port.
Chapter 1: Installation Warranty Registration Allied Telesis hardware products are covered under limited warranties. Some products have a longer warranty coverage than others. The AT-MCF2000S Stacking Module has a limited warranty of 5 years. All Allied Telesis warranties are subject to the terms and conditions set out on the Allied Telesis website at www.alliedtelesis.com/warranty.
Appendix A Technical Specifications Physical Dimensions: HxWxD 3.1 cm x 9.7 cm x 20.8 cm (1.2 in x 3.8 in x 8.2 in) Weight: .295 g (0.
Appendix A: Technical Specifications Standards & Compliance IEEE 802.3 10T Ethernet IEEE 802.3u 100TX Fast Ethernet IEEE 802.