AT-MCF6ST, SC AT-MCF6VF, SM AT-MCF12ST, SC AT-MCF12VF, SM Multichannel Ethernet Media Converters Installation Guide PN 613-10830-00 Rev C
Copyright © 2004 Allied Telesyn, Inc. www.alliedtelesyn.com All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn, Inc.
Electrical Safety and Emission Statement Standards: This product meets the following standards U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Electrical Safety and Emission Statement IMPORTANTE: O Anexo B contém advertências de segurança traduzidas para instalar este equipamento. Quando vir o símbolo , leia a advertência de segurança traduzida no seu idioma no Anexo A. IMPORTANTE: El Apéndice B contiene mensajes de seguridad traducidos para la instalación de este equipo. Cuando vea el símbolo , vaya al Apéndice B para ver el mensaje de seguridad traducido a su idioma.
Contents Electrical Safety and Emission Statement ..............................................iii Contents ............................................................................................................ v Preface............................................................................................................. vii Where to Find Related Guides......................................................................... vii Document Conventions ...........................................
Contents Chapter 2 Installation ..................................................................................................... 13 Selecting a Site for the Media Converter ........................................................ 13 Planning the Installation ................................................................................. 13 Checking the Media Converter Package ......................................................... 15 Reviewing Safety Precautions....................................
Preface This guide contains instructions on how to install and configure the AT-MCF6xx and AT-MCF12xx Series Multichannel Ethernet Media Converters. Where to Find Related Guides The Allied Telesyn web site at www.alliedtelesyn.com offers you an easy way to access the most recent documentation, software, and technical information for all of our products. For product guides, select “Support & Services” from our web site.
Preface Contacting Allied Telesyn This section provides Allied Telesyn contact information for technical support as well as sales or corporate information. Online Support You can request technical support online by accessing the Allied Telesyn Knowledge Base from the following web site: http://kb.alliedtelesyn.com. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
Chapter 1 Overview The Ethernet AT-MCF6xx and the AT-MCF12xx Series Multichannel Media Converters are designed to extend the reach of your network by converting your twisted pair cabling into fiber optic cabling. These products, which transfer Ethernet data between 10Base-T and 10Base-FL technologies, enable you to quickly and easily interconnect the nodes in your network to distances of 2 kilometers (1.24 miles) to 15 kilometers (9.3 miles), depending on the model.
Overview System Models Table 1 lists the available system models. Table 1 Models of the AT-MCF6xx and AT-MCF12xx Series Multichannel Media Converters 1 2 Model Number of Media Converter Channels Type of Fiber Optic Connector Type of Fiber Optic Cabling Maximum Distance1 AT-MCF6ST 6 ST Multimode 2 km (1.24 mi) AT-MCF6SC 6 SC Multimode 2 km (1.24 mi) AT-MCF6VF 6 VF-45 Multimode 2 km (1.24 mi) AT-MCF6SM 6 SC Single-mode 15 km (9.3 mi) AT-MCF12ST 12 ST Multimode 2 km (1.
AT-MCF6xx and AT-MCF12xx Installation Guide Front and Back Panel Components This section describes the features and components of the AT-MCF6xx and AT-MCF12xx Series Multichannel Media Converters. Figure 1 illustrates the front panel of an AT-MCF6xx system.
Overview Table 2 Power Supply and Link Test Switch LEDs LED Color Indicates MAIN Green The main power supply is functioning normally. Flashing Green The main power supply is failing or has failed. Green The optional redundant power supply, if installed, is functioning normally. BCKP Flashing Green The optional redundant power supply, if installed, is failing or has failed. NORM Green The unit is not performing a link test.
AT-MCF6xx and AT-MCF12xx Installation Guide Twisted Pair and Fiber Optic Ports The twisted pair and fiber optic ports on the unit are paired together (see Figure 3). Each pair is referred to as a “channel” and each channel functions as an independent media converter. The AT-MCF6xx unit has six channels while the AT-MCF12xx unit has twelve channels.
Overview Link Test Switch The Link Test switch is a fast and easy way for you to test the integrity of the fiber optic connections to the fiber optic ports on the media converter (see Figure 4). The AT-MCF6xx unit has one Link Test switch which is used to test all six fiber optic ports on the unit.
AT-MCF6xx and AT-MCF12xx Installation Guide MissingLink Feature The MissingLink™ feature enables the twisted pair and fiber optic ports of each channel on the media converter to pass the “Link” status of their connections to each other. When a channel detects a problem with one of the ports, such as the loss of connection to a node, the channel shuts down the connection to the other port of the channel, thus notifying the node that the connection has been lost.
Overview Reset Button The Reset button allows you to reset the ports on the unit. You might need to reset the ports after completing the installation or after adding or swapping a power supply. You must reset the unit after a power disruption or whenever a general power failure status is observed. Power Inlet The unit does not have an ON/OFF power switch. Power is applied to and removed from the system by connecting and disconnecting the power cable.
AT-MCF6xx and AT-MCF12xx Installation Guide 10Base-T, Management, and RS-232 Ports These ports, as shown in Figure 6, are reserved for future development.
Overview Network Topology The value of the AT-MCF6xx and AT-MCF12xx Series Multichannel Media Converters is that they allow you to extend the reach of your network and to interconnect widespread network devices and subnetworks into one integrated network. Figure 7 on page 11 illustrates an example of a network that incorporates a model AT-MCF6SC unit to interconnect dispersed network devices. The model has SC type fiber optic connectors and a range of 2 kilometers (1.24 miles) on the fiber optic ports.
AT-MCF6xx and AT-MCF12xx Installation Guide AT-8224XL Ethernet Switch 10BASE-T / 100BASE-TX FAST ETHERNET SWITCH A 10BASE-T / 100BASE-TX PORT ACTIVITY 1X 3X 5X 7X 9X 11X 13X 15X 17X 19X 21X 23X 2X 4X 6X 8X 10X 12X 14X 16X 18X 20X 22X 24X 100M LINK / L /A ACTIVITY RS-232 TERMINAL PORT 10M LINK / HALF DUP/ FULL DUP D/C STATUS ACTIVITY COL 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 FAULT L /A D/C B RPS L /A PWR D/C RESET
Chapter 2 Installation The following sections explain how to install the unit onto your network. The unit can be installed as a standalone system (such as on a desk) or in a standard 19-inch rack. Selecting a Site for the Media Converter Be sure to observe the following requirements when choosing a site for your media converter: ❑ Select a site that is dust-free and moisture-free. ❑ Do not block the ventilation openings on the unit.
Installation ❑ Refer to Table 4 for the twisted pair cabling specifications. Table 4 Twisted Pair Cabling Specifications Specifications Type Shielded or unshielded twisted pair Cable Category 3 or better Maximum Distance 100 meters (328 feet) External Device Network adapter card, repeater, switch, router, or hub ❑ Use a straight-through cable to connect a hub or switch to a twisted pair port on the media converter.
AT-MCF6xx and AT-MCF12xx Installation Guide Check the attenuation on the fiber optic cabling after installation. Refer to Table for the maximum allowable loss budget.
Installation Reviewing Safety Precautions Please review the following safety precautions before you install the media converter. Laser Class 1 laser product. 6 Laser Do not stare into the laser beam. 7 Warning Electric Shock Hazard: To prevent electric shock, do not remove the cover. There are no user-serviceable parts inside. The unit contains hazardous voltages and should only be opened by a trained and qualified technician.
AT-MCF6xx and AT-MCF12xx Installation Guide Caution Operating Temperature: This product is designed for a maximum ambient temperature of 40°C. 14 Caution All Countries: Install this product in accordance with local and National Electric Codes. 15 Installing the Media Converter as a Standalone Unit The media converter can be installed as a standalone unit (for instance, on a table) or in a standard 19-inch rack.
Installation Note Do not remove the back panel covering the expansion slot for the redundant power supply unless you intend to install the unit. 6. Plug the power cord into the back of the unit and plug the other end of the power cord into a power outlet. If you installed an optional redundant power supply, plug its power cord into the power supply and the other end into a power outlet. Caution When connecting a power cord, you should always plug the power cord into the media converter first.
AT-MCF6xx and AT-MCF12xx Installation Guide Installing the Media Converter in a Rack To install the unit in a 19-inch rack, perform the following steps: 1. Remove all equipment from the shipping package and store the package in a safe place. Caution Do not remove the dust covers from the fiber optic ports on the media converter until you are ready to connect the cables. Dust contamination can adversely impact the operation of the fiber optic ports. 2.
Installation Note To ensure adequate cooling, there should be a minimum of 1 centimeter (0.39 inches) of ventilation space between the unit and any other device installed in the rack. 7. Plug the power cord into the back of the unit and plug the other end of the power cord into a power outlet. If you installed an optional redundant power supply, plug its power cord into the power supply and the other end into a power outlet.
AT-MCF6xx and AT-MCF12xx Installation Guide Verifying the Installation The procedure in this section has you test the unit by performing a link test. A link test will determine whether each fiber optic port on the unit is receiving a signal from the node connected to it. You should perform this test immediately after you have installed the unit or whenever you need to test the integrity of the fiber optic connections to the fiber optic ports on the unit. To perform a link test, follow these steps: 1.
Chapter 3 Troubleshooting This section contains guidelines for troubleshooting the media converter in the event a problem occurs. If the Main LED is OFF, check the following: ❑ Check to be sure that the power cord for the main power supply is securely connected to the power supply and the power outlet. ❑ Check that the power outlet has power by connecting another device to it. ❑ Check that the input power source is within the acceptable range. For AC models, the range is between 100 and 240 VAC.
Troubleshooting If the F-LNK LED for a fiber optic port is OFF, check the following: ❑ Check to be sure the node connected to the port is powered ON. ❑ Check to be sure that the fiber optic cable is properly connected to the fiber optic port. ❑ Check to be sure that the node connected to the port is operating at 10 Mbps. ❑ Verify that the maximum allowable loss budget on the fiber optic cable is within acceptable limits (see Table 4).
Appendix A Technical Specifications Physical Specifications Dimensions: WxHxD 44.1 cm x 26.5 cm x 4.4 cm (17.3 in x 10.4 in x 1.75 in) Weight: 4.2 kg (9.2 lbs) Environmental Specifications Operating Temperature: 0° C to 40° C (32° F to 104° F) Storage Temperature: -25° C to 70° C (-13° F to 158° F) Operating Humidity: 5% to 90% (noncondensing) Storage Humidity: 5% to 95% (noncondensing) Operating Altitude: 3,000 m (approx. 10,000 ft) Non-operating Altitude: 4,000 m (approx.
Technical Specifications Safety and Electromagnetic Emissions Certifications EMI/RFI: FCC Class A, EN55022 Class A, VCCI Class A, ICES Class A Electrical Safety: EN60950, UL1950, CSA950 Immunity: EN50082-1 Laser: EN60825 Pinout Assignments Figure 9 shows the pinout assignments for the RJ-45 connector. 8 1 8 1 Figure 9 RJ-45 Pin Assignments Table 7 lists the RJ-45 connector pins and their signals used in Port 1 - Port 4 when these port are operating in either MDI or MDI-X configuration.
Appendix B Translated Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Translated Safety and Emission Information Standards: This product meets the following standards: U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AT-MCF6xx and AT-MCF12xx Installation Guide 10 CAUTION: POWER CORD IS USED AS A DISCONNECTION DEVICE. TO DEENERGIZE EQUIPMENT, disconnect the power cord. 11 ELECTRICAL - TYPE CLASS 1 EQUIPMENT THIS EQUIPMENT MUST BE EARTHED. Power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
Translated Safety and Emission Information Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. 1 Hochfrequenzstörung 2 WARNUNG: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen. 3 Störsicherheit EN50082-1 4 Elektrische Sicherheit EN60950, UL1950, CSA 950 5 Laser EN60825 EN55022 Klasse A SICHERHEIT 6 WARNUNG: Laserprodukt der Klasse 1.
AT-MCF6xx and AT-MCF12xx Installation Guide Standarder: Dette produkt tilfredsstiller de følgende standarder. 1 Radiofrekvens forstyrrelsesemission 2 ADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger. EN55022 Klasse A 3 Immunitet EN50082-1 4 Elektrisk sikkerhed EN60950, UL1950, CSA 950 5 Laser EN60825 SIKKERHED 6 ADVARSEL Laserprodukt av klasse 1.
Translated Safety and Emission Information Eisen: Dit product voldoet aan de volgende eisen. 1 RFI Emissie 2 WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen. 3 Immuniteit EN50082-1 4 Electrische Veiligheid EN60950, UL1950, CSA 950 5 Laser EN60825 6 WAARSHUWING Klasse-1 laser produkt. 7 WAARCHUWING Neit in de straal staren.
AT-MCF6xx and AT-MCF12xx Installation Guide Normes: ce produit est conforme aux normes de suivantes: 1 Emission d’interférences radioélectriquesEN55022 Classe A 2 MISE EN GARDE : dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates. 3 Immunité EN50082 - 1 4 Sécurité électrique EN60950, UL1950, CSA 950 5 Laser EN60825 SÉCURITÉ. 6 ATTENTION Producit laser di classe 1.
Translated Safety and Emission Information Standardit: Tämä tuote on seuraavien standardien mukainen. 1 Radioaaltojen häirintä 2 VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. 3 Kestävyys EN50082-1 4 Sähköturvallisuus EN60950, UL1950, CSA 950 5 Laser EN60825 EN55022 Luokka A TURVALLISUUS 6 VAROITUS Luokan 1 Lasertuote. 7 VARIOTUS Älä katso säteeseen.
AT-MCF6xx and AT-MCF12xx Installation Guide Standard: Questo prodotto è conforme ai seguenti standard. 1 Emissione RFI (interferenza di radiofrequenza) EN55022 Classe A 2 AVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti. 3 Immunità EN50082-1 4 Sicurezza elettrica EN60950, UL1950, CSA 950 5 Laser EN60825 NORME DI SICUREZZA 6 AVVERTENZA Prodotto laser di Classe 1.
Translated Safety and Emission Information Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. 1 RFI stråling 2 ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. 3 Immunitet EN50082-1 4 Elektrisk sikkerhet EN60950, UL1950, CSA 950 5 Laser EN60825 6 ADVARSEL Laserprodukt av klasse 1. 7 ADVARSAL Stirr ikke på strålen.
AT-MCF6xx and AT-MCF12xx Installation Guide Padrões: Este produto atende aos seguintes padrões. 1 Emissão de interferência de radiofrequênciaEN55022 Classe A 2 AVISO: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas. 3 Imunidade EN50082-1 4 Segurança Eléctrica EN60950, UL1950, CSA 950 5 Laser EN60825 SEGURANÇA 6 AVISO Produto laser de classe 1.
Estándares: Este producto cumple con los siguientes estándares. 1 Emisión RFI 2 ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. 3 Inmunidad EN50082-1 4 Seguridad eléctrica EN60950, UL1950, CSA 950 5 Laser EN60825 6 ¡ADVERTENCIA! Producto láser Clase 1. 7 ¡ADVERTENCIA! No mirat fijamente el haz.
AT-MCF6xx and AT-MCF12xx Installation Guide Standarder: Denna produkt uppfyller följande standarder. 1 Radiostörning 2 VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. EN55022 Klass A 3 Immunitet EN50082-1 4 Elsäkerhet EN60950, UL1950, CSA 950 5 Laser EN60825 SÄKERHET 6 VARNING! Laserprodukt av klass 1. 7 VARNING! Laserstrålning när enheten är öppen.