AT-MC104XL AT-MC104LH AT-MC104SC/FS3, FS4 AT-MC104ST/FS3, FS4 Version 3 Fast Ethernet Media Converters Installation Guide PN 613-10781-00 Rev D
Copyright 2000 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086 USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International Corp.
Safety Warnings Standards: This product meets the following standards. U.S. Federal Communications Commission DECLARATION OF CONFORMITY Manufacture Name: Allied Telesyn International, Corp.
EUROPE - EU Use TÜV licensed AC adapter of DC 12V, 500mA. UK Use a UK Safety Approved AC adapter of DC 12V, minimum 500mA. Important: Appendix A contains translated safety statements for installing this equipment. When you see the !, go to Appendix A for the translated safety statement in your language. Wichtig: Anhang A enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts. Wenn Sie ! sehen, schlagen Sie in Anhang A den übersetzten Sicherheitshinweis in Ihrer Sprache nach.
Table of Contents Safety Warnings ............................................................................................ iii Welcome to Allied Telesyn ......................................................................... vii Where to Find Web-based Guides ................................................................... vii Document Conventions .................................................................................... vii Contacting Allied Telesyn Technical Support....................
Appendix A Translated Safety Statements ................................................................... 19 Appendix B AT-MC104 Series Installation Guide Feedback .................................... 29 Appendix C Technical Support Fax Order ...................................................................
Welcome to Allied Telesyn This guide contains instructions on how to install an AT-MC104 Series Fast Ethernet Media Converter. Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com provides you with an easy way to access the most recent documentation and technical information for all of our products. For product guides, you can go directly to the following web page: www.alliedtelesyn.com/support/prd_libs.htm.
Contacting Allied Telesyn Technical Support There are several ways to contact Allied Telesyn technical support: online, telephone, fax or e-mail. Online Support You can request technical support online by filling out the Technical Support Form at www.alliedtelesyn.com/forms/support.htm.
AT-MC104 Series Installation Guide Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
For Sales or Corporate Information Allied Telesyn International, Corp. 19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191 Allied Telesyn International, Corp.
AT-MC104 Series Fast Ethernet Media Converters The AT-MC104 Series Media Converters include the following models: ❑ AT-MC104XL ❑ AT-MC104ST/FS3 ❑ AT-MC104LH ❑ AT-MC104SC/FS4 ❑ AT-MC104SC/FS3 ❑ AT-MC104ST/FS4 AT-MC104 Series Fast Ethernet Media Converters are designed to extend the distance of your network by interconnecting multimode fiber optic cabling and single-mode fiber optic cabling. The media converters allow you to interconnect LAN devices that are physically separated by large distances.
Table 1 list the maximum cabling distances for each model. Table 1 Maximum Operating Distances Type of Connector Model Maximum Distance1 Port 1 (Single-mode) Port 2 (Multimode) Port 1 (Single-mode) Port 2 (Multimode) AT-MC104XL SC SC 15 km (9.3 mi) 2 km (1.2 mi) AT-MC104LH SC SC 40 km (24.8 mi) 2 km (1.2 mi) AT-MC104SC/FS3 SC SC 75 km (46.5 mi) 2 km (1.2 mi) AT-MC104ST/FS3 ST ST 75 km (46.5 mi) 2 km (1.2 mi) AT-MC104SC/FS4 SC SC 100 km (62 mi) 2 km (1.
AT-MC104 Series Installation Guide Status LEDs Table 2 defines the system LEDs. Table 2 Status LEDs LED State Color Description LNK ON Green Link is established on the port. ACT ON Green Data is being received on the port. PWR ON Green Power is applied. M/L ON ON Green The MissingLink feature is activated on the media converter. OFF The MissingLink feature is disabled and the unit is operating in the link test mode.
MissingLink. The MissingLink feature activates the fiber optic ports on the media converter to pass the “Link” status of their connections to each other. When the media converter detects a problem with one of the ports, such as the loss of connection to a node, the media converter shuts down the connection to the other port, thus notifying the node that the connection has been lost.
AT-MC104 Series Installation Guide Network Topologies Figure 3 shows two typical network configurations of the media converter. 10/100Base-TX Switch AT-MC103XL AT-MC104XL 100 meters CLASS 1 LASER PRODUCT DO NOT STARE INTO BEAM TX M/L ON RX 15 kilometers/ 49,213 ft (9.
Installing the Media Converter The following sections explain how to install the media converter. The media converter can be installed either as a standalone unit (such as on a table) or in an AT-MCR12 chassis or an AT-TRAY4 tray. Planning the Installation Be sure to observe the following guidelines when planning the installation of your media converter. 6 ❑ The nodes connected to the media converter must operate at 100 Mbps.
AT-MC104 Series Installation Guide Cable Specifications Table 3, Table 4, and Table 5 list the IEEE 802.3u cabling specifications for the AT-MC104 Series Media Converter. Table 3 Multimode Port Specifications Cable Type 50/125 or 62.5/125 micron multimode fiber Maximum Distance 2 km (1.2 mi) Table 4 Single-mode Port Specifications (Full-duplex) Media Converter Type of Fiber Optic Cable AT-MC104XL 50/125 or 62.
Table 5 Single-mode Port Specifications (Half-duplex)1 Number of Media Converters One Media Converter Inline Two Media Converters Inline Connected Devices Maximum Distance Switch to switch 372 m (1,221 ft) Workstation to switch 372 m (1,221 ft) Switch to Class I repeater 137 m (450 ft) Switch to Class II repeater 185 m (607 ft) Switch to switch 332 m (1,089 ft) Workstation to switch 322 m (1, 089 ft) Switch to Class I repeater 97 m (318 ft) Switch to Class II repeater 145 m (476 ft) 1.
AT-MC104 Series Installation Guide Verifying the Package Contents Make sure the following items are included in your media converter package. If any of the following items are missing or damaged, contact your sales representative.
Installing the Media Converter The following procedure explains how to install the media converter. If you are building a back-to-back installation, please review the following. See Figure 3 for an illustration of a back-to-back-media converter configuration. ❑ During installation, setup, and testing of back-to-back media converters, make sure each media converters Link Test/MissingLink button is in the LNK TST (OUT) position.
AT-MC104 Series Installation Guide 7. Remove the dust covers from the fiber optic connectors. 8. Connect the fiber optic cables to their respective ports on the media converter. 9. Connect the other end of the fiber cable to the desired end station. Note End stations used with the media converter must operate with the same duplex mode (either both full-duplex or both half-duplex). Go to “Testing the Installation” on page 11 for instructions on how to test the unit.
4. Check the two LNK LEDs. They should be green, indicating that the media converter is receiving a signal from the nodes connected to the ports. If a LNK LED is not green, check the following: — The node connected to the port is powered ON. — The fiber optic cable is securely connected to the fiber optic port. — The appropriate type of fiber optic cable for the port is being used. Refer to Table 3 through Table 5 for cable specifications.
AT-MC104 Series Installation Guide Warranty Registration When you finish the installation, register your product by completing the enclosed warranty card and sending it in. You can also visit our web site at www.alliedtelesyn.com/forms/warranty.htm and fill out the registration online. Technical Specifications Physical Specifications Dimensions: WxDxH 10.5 cm x 9.5 cm x 2.5 cm (4.125 in x 3.75 in x 1.
Single-mode Port Specifications Table 6 Fiber Optic Transmitter Launch Power (dBm)2 Fiber Type1 Fiber Optic Diameter (microns) AT-MC104XL SMF 9/125 1310 nm -8.0 -11.5 -15.0 AT-MC104LH SMF 9/125 1310 nm 0.0 -3.0 -5.0 AT-MC104SC/FS3 and AT-MC104ST/FS3 SMF 9/125 1310 nm 0.0 -2.0 -4.0 AT-MC104SC/FS4 and AT-MC104ST/FS4 SMF 9/125 1550 nm 0.0 -1.5 -3.0 Model Optical Frequency Max. Avg. Min. 1. SMF = Single-mode Fiber 2.
AT-MC104 Series Installation Guide Table 8 Fiber Optic Datalink Model Fiber Optic Diameter (microns) Optical Freq. Min. Power/ Link Budget (dB) Avg. Signal Loss (dB) Min. Distance Spec.1 Max. Distance Spec. (Full-duplex only) AT-MC104XL 9/125 1310 nm 16.0 19.50 0 15 km (9.3 mi) AT-MC104LH 9/125 1310 nm 30.0 35.00 0 40 km (24.8 mi) AT-MC104SC/FS3 9/125 and AT-MC104ST/FS3 1310 nm 33.0 35.00 15 km (9.3 mi) 75 km (46.5 mi) AT-MC104SC/FS4 9/125 and AT-MC104ST/FS4 1550 nm 34.0 35.
Multimode Port Specifications (All Models) Table 10 Fiber Optic Transmitter Fiber Optic Diameter (microns) Fiber Type1 Optical Frequency Launch Power (dBm)2 Maximum Average Minimum MMF 50/125 1310 nm -14.0 -20.3 -22.5 MMF 62.5/125 1310 nm -14.0 -16.8 -19.0 1. MMF = Multimode Fiber 2. Launch power measured at one meter from the transmitter.
AT-MC104 Series Installation Guide Table 13 Fiber Optic Loss Specifications (Benchmarks) Fiber Type1 MMF Fiber Optic Diameter (microns) Optical Frequency Typical Loss Factor (dB/km) 50/125 850 nm 3.00 3.50 400 62.5/125 850 nm 3.00 3.75 200 100/140 850 nm 4.00 4.00 100 50/125 1310 nm 1.00 1.50 400 62.5/125 1310 nm 1.00 1.
Appendix A Translated Safety Statements Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Standards: This product meets the following standards. U.S. Federal Communications Commission DECLARATION OF CONFORMITY Manufacture Name: Manufacture Address: Allied Telesyn International, Corp.
AT-MC104 Series Installation Guide At time of installation, the Fiber Optic Lasers comply with FDA Radiation Performance Standard 21CFR Subchapter J, applicable at date of manufacture. Use of controls or adjustments of performance or procedures other than those specified herein may result in hazardous radiation exposure. SAFETY !7 LIGHTNING DANGER DANGER: DO NOT WORK on equipment or CABLES during periods of LIGHTNING ACTIVITY.
! 10 BETRIEBSTEMPERATUR Dieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr als 40° C entworfen. ! 11 ALLE LÄNDER: Installation muß örtlichen und nationalen elektrischen Vorschriften entsprechen. Standarder: Dette produkt tilfredsstiller de følgende standarder. !1 Radiofrekvens forstyrrelsesemission EN55022 Klasse B !2 Immunitet EN50082-1 1997 !3 Elektrisk sikkerhed TUV-EN60950, UL1950, CSA 950 !4 Laser EN60825 !5 Advarsel Laserprodukt av klasse 1.
AT-MC104 Series Installation Guide !7 GEVAAR VOOR BLIKSEMINSLAG GEVAAR: NIET aan toestellen of KABELS WERKEN bij BLIKSEM. !8 VENTILATIEGATEN NIET BLOKKEREN !9 Stroom mag alleen via de adapter naar het apparaat toegevoerd worden. EUROPE - EU Gebruik een door TÜV gekeurde wisselstroomadapter van 12 Volt gelijkstroom, 500 milliampères. ! 10 BEDRIJFSTEMPERATUUR De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius.
Standardit: Tämä tuote on seuraavien standardien mukainen. !1 Radioaaltojen häirintä EN55022 Luokka B !2 Kestävyys EN50082-1 1997 !3 Sähköturvallisuus TUV-EN60950, UL1950, CSA 950 !4 Laser EN60825 !5 Varoitus Luokan 1 Lasertuote. !6 Variotus Älä katso säteeseen. TURVALLISUUS !7 SALAMANISKUVAARA ENGENVAARA: ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA SALAMOINNIN AIKANA. !8 ÄLÄ TUKI ILMAREIKIÄ !9 Tähtipisteeseen (hub) syötettävän virran pitää tulla ainoastaan sovittimesta.
AT-MC104 Series Installation Guide !9 Questo dispositivo deve essere alimentato solo mediante l’adattatore. EUROPE - EU Utilizzare l’adattatore per c.a. da 12 V c.c. e 500 mA conforme alla normativa TÜV. ! 10 TEMPERATURA DI FUNZIONAMENTO Questo prodotto è concepito per una temperatura ambientale massima di 40 gradi centigradi. ! 11 TUTTI I PAESI: installare il prodotto in conformità delle vigenti normative elettriche nazionali.
Padrões: Este produto atende aos seguintes padrões. !1 Emissão De Interferência De Radiofrequência EN55022 Classe B !2 Imunidade EN50082-1 1997 !3 Segurança Eléctrica TUV-EN60950, UL1950, CSA 950 !4 Laser EN60825 !5 Aviso Produto laser de classe 1. !6 Aviso Não olhe fixamente para o raio. SEGURANÇA !7 PERIGO DE CHOQUE CAUSADO POR RAIO PERIGO: NÃO TRABALHE no equipamento ou nos CABOS durante períodos suscetíveis a QUEDAS DE RAIO.
AT-MC104 Series Installation Guide !9 La energía para el dispositivo central o "hub" debe provenir únicamente del adaptador. EUROPE - EU Utilizar un adaptador de corriente alterna autorizado TÜV de 12 voltios de corriente continua y 500 miliamperios. ! 10 TEMPERATURA REQUERIDA PARA LA OPERACIÓN Este producto está diseñado para una temperatura ambiental máxima de 40 grados C. ! 11 PARA TODOS LOS PAÍSES: Monte el producto de acuerdo con los Códigos Eléctricos locales y nacionales.
Appendix B AT-MC104 Series Installation Guide Feedback Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.
Appendix C Technical Support Fax Order Name _________________________________________________________________ Company ______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province_______________________________ Zip/Postal Code ________________ Country_______________________________ Phone ______________________________ Fax_______________________________ Incident Summary Model number of Allied