AT-MC101XL AT-MC102XL AT-MC103XL AT-MC103LH AT-MC103SC/FS3, FS4 AT-MC103ST/FS3, FS4 Version 3 Fast Ethernet Media Converters Installation Guide PN 613-10771-00 Rev D
Copyright 2000 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086 USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp.
Safety Warnings Standards: This product meets the following standards. U.S. Federal Communications Commission DECLARATION OF CONFORMITY Manufacture Name: Allied Telesyn International, Corp.
Laser EN60825 ! 5 Power to the hub must be sourced only from the adapter. ! 10 USA/CANADA Use a UL Listed/CSA Certified AC adapter of DC 12V, 500mA. EUROPE - EU Use TÜV licensed AC adapter of DC 12V, 500mA. UK Use a UK Safety Approved AC adapter of DC 12V, minimum 500mA. Important: Appendix A contains translated safety statements for installing this equipment. When you see the !, go to Appendix A for the translated safety statement in your language.
Table of Contents Safety Warnings ............................................................................................ iii Welcome to Allied Telesyn ......................................................................... vii Where to Find Web-based Guides ................................................................... vii Document Conventions .................................................................................... vii Contacting Allied Telesyn Technical Support....................
Appendix A Translated Electrical Safety and Emission Information .................... 21 Appendix B AT-MC100 Series Installation Guide Feedback .................................... 35 Appendix C Technical Support Fax Order ................................................................... 37 Incident Summary.....................................................................................
Welcome to Allied Telesyn This guide contains instructions on how to install an AT-MC100 Series Fast Ethernet Media Converter. Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com provides you with an easy way to access the most recent documentation and technical information for all of our products. For product guides, you can go directly to the following web page: www.alliedtelesyn.com/support/prd_libs.htm.
Contacting Allied Telesyn Technical Support There are several ways to contact Allied Telesyn technical support: online, telephone, fax or e-mail. Online Support You can request technical support online by filling out the Technical Support Form at www.alliedtelesyn.com/forms/support.htm.
AT-MC100 Series Installation Guide Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
For Sales or Corporate Information Allied Telesyn International, Corp. 19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191 Allied Telesyn International, Corp.
AT-MC100 Series Fast Ethernet Media Converters The AT-MC100 Series Fast Ethernet Media Converters include the following models: ❑ AT-MC101XL ❑ AT-MC103SC/FS3 ❑ AT-MC102XL ❑ AT-MC103ST/FS3 ❑ AT-MC103XL ❑ AT-MC103SC/FS4 ❑ AT-MC103LH ❑ AT-MC103ST/FS4 The AT-MC100 Series Fast Ethernet Media Converters are designed to extend the distance of your network by interconnecting LAN devices that are physically separated by large distances.
Table 1 Maximum Cabling Distances Type of Connector Model Maximum Distance1 Port 1 (100Base-FX) Port 2 (100Base-TX) Port 1 (100Base-FX) Port 2 (100Base-TX) AT-MC101XL ST RJ-45 2 km (1.2 mi) 100 m (328 ft) AT-MC102XL SC RJ-45 2 km (1.2 mi) 100 m (328 ft) AT-MC103XL SC RJ-45 15 km (9.3 mi) 100 m (328 ft) AT-MC103LH SC RJ-45 40 km (24.8 mi) 100 m (328 ft) AT-MC103SC/FS3 SC RJ-45 75 km (46.5 mi) 100 m (328 ft) AT-MC103ST/FS3 ST RJ-45 75 km (46.
AT-MC100 Series Installation Guide Status LEDs Table 2 defines the system LEDs. Table 2 Status LEDs LED State Color LNK ON Green A link has been established on the port. ACT ON Green Data is being received on the port. FDX ON Green Indicates that the unit is operating in full-duplex mode. OFF Description Indicates that the unit is operating in half-duplex mode. PWR ON Green Power is applied. M/L ON ON Green The MissingLink feature is activated on the media converter.
Link Test/MissingLink Button The Link Test/MissingLink button allows you to perform a link test on the ports on the media converter. This button also allows you to activate the MissingLink feature on the unit. Both features are describe in the following section. Link Test. The link test is a fast and easy way for you to test the connections between the ports on the media converter and the nodes that are connected to the ports.
AT-MC100 Series Installation Guide Auto-negotiation Button The auto-negotiation button, located on the front panel, disables the autonegotiation feature (IEEE 802.3u) of the media converter. The media converter uses auto-negotiation to determine the duplex mode of the ports. The duplex mode refers to the manner in which a node sends and receives data on the network. Depending on its capabilities, a node can operate in either half- or full-duplex mode.
You can resolve the mismatch in one of two ways: ❑ Manually configure Unit 2, if possible, so that the port connected to the media converter is set to half-duplex. ❑ Disable auto-negotiation on the media converter using the autonegotiation button. With auto-negotiation on the media converter disabled, Unit 2 will assume that the converter is capable of only halfduplex operation, thus eliminating the mismatch in duplex modes between the end stations.
AT-MC100 Series Installation Guide Network Topologies Figure 4 shows a network configuration where two AT-8224XL switches have been interconnected with an AT-MC102XL Media Converter.
Installing the Media Converter The following section explain how to install the media converter. The media converter can be installed either as a standalone unit (such as on a table) or in an AT-MCR12 chassis or in an AT-TRAY4 tray. Planning the Installation Be sure to observe the following guidelines when planning the installation of your media converter. ❑ The nodes connected to the media converter must operate at 100 Mbps.
AT-MC100 Series Installation Guide Table 4 100Base-FX Fiber Optic Port Specifications (Full-duplex) Model Type of Fiber Optic Cable Maximum Distance Maximum Allowable Loss Budget AT-MC101XL 50/125 or 62.5/125 micron multimode 2 km (1.2 mi) 13 dB at 1310 nm AT-MC102XL 50/125 or 62.5/125 micron multimode 2 km (1.2 mi) 13 dB at 1310 nm AT-MC103XL 9/125 micron single-mode 15 km (9.3 mi) 16 dB at 1310 nm AT-MC103LH 9/125 micron single-mode 40 km (24.
Verifying the Package Contents Make sure the following items are included in your media converter package. If any of the following items are missing or damaged, contact your sales representative. ❑ One AT-MC100 Series Fast Ethernet Media Converter ❑ Four protective feet (for standalone use only) ❑ External AC/DC power adapter ❑ This installation guide ❑ Warranty card Reviewing Safety Precautions Please review the following safety precautions before you begin to install the media converter.
AT-MC100 Series Installation Guide Installing the Media Converter The following procedure explains how to install the media converter as a standalone unit. If you are building a back-to-back installation, please review the following. See Figure 5 for an illustration of a back-to-back-media converter configuration. ❑ During installation, setup, and testing of back-to-back media converters, make sure each media converters Link Test/MissingLink button is in the LNK TST (OUT) position.
6. Plug the AC/DC power adapter into an appropriate AC power outlet and insert the power plug into the DC receptacle located on the rear panel. (This step does not apply if you installed the unit in an AT-MCR12 chassis.) 12 V D C Figure 6 12 V DC Connector on Rear Panel 7. Verify that the Power LED is green. 8. Remove the dust cover from the fiber optic connector. 9. Connect the fiber optic cable to the fiber optic port on the media converter. 10.
AT-MC100 Series Installation Guide CLASS 1 LASER PRODUCT DO NOT STARE INTO BEAM M/L ON TX RX 100Base-FX 100Base-TX FDX LNK A/N ON MDI ACT A/N OFF MDI-X LNK PWR LNK TST ACT M/L ON SINGLE MODE MC103SC/FS3 FAST ETHERNET MEDIA CONVERTER MDI MDI-X Figure 7 MDI/MDI-X Switch 12. Connect a Category 5 or better twisted pair cable to the RJ-45 connector. Connect the other end of the twisted pair cable to the desired end station.
2. Turn ON the nodes (such as the hubs or switches) that are connected to the media converter. 3. Set the Link Test/MissingLink button on the media converter to the LNK TST (IN) position. 4. Check the two LNK LEDs. They should be green, indicating that the media converter is receiving a signal from the nodes connected to the ports. If the LNK LED is not green, check the following: — The node connected to the port is powered ON. — The fiber optic cable is securely connected to the fiber optic port.
AT-MC100 Series Installation Guide If you are still experiencing problems after testing the installation, contact Allied Telesyn Technical Support. Technical support is offered online, telephone, fax or e-mail. Refer to “Contacting Allied Telesyn Technical Support” on page viii or visit our web site at www.alliedtelesyn.com for support information. Warranty Registration When you finish the installation, register your product by completing the enclosed warranty card and sending it in.
Power Requirements Input Supply Voltage: 12 V DC ± 5% Maximum Current: 500 mA Power Consumption: 6W 100Base-FX Port Specifications Table 6 Fiber Optic Transmitter Model Fiber Type1 Fiber Optic Diameter (microns) Optical Frequency (nm) Launch Power (dBm)2 Max. Avg. Min. AT-MC101XL and AT-MC102XL MMF 50/125 1310 nm -14.0 -20.3 -22.5 MMF 62.5/125 1310 nm -14.0 -16.8 -19.0 AT-MC103XL SMF 9/125 1310 nm -8.0 -11.5 -15.0 AT-MC103LH SMF 9/125 1310 nm 0.0 -3.0 -5.
AT-MC100 Series Installation Guide Table 7 Fiber Optic Receiver Model Fiber Type1 Fiber Optic Diameter (microns) Optical Frequency (nm) Receive Power (dBm) Min. Typical Saturation AT-MC101XL and AT-MC102XL MMF 50/125 or 62.5/125 1310 nm -31.8 -34.5 -14.0 AT-MC103XL SMF 9/125 1310 nm -31.0 -31.0 -8.0 AT-MC103LH SMF 9/125 1310 nm -35.0 -38.0 0.0 AT-MC103SC/FS3 and AT-MC103ST/FS3 SMF 9/125 1310 nm -37.0 -37.0 -3.0 AT-MC103SC/FS4 and AT-MC103ST/FS4 SMF 9/125 1550 nm -37.
Table 8 Fiber Optic Datalink Model Fiber Type1 Minimum Power / Link Budget (dB) Average Signal Loss (dB) Minimum Distance Spec.2 Maximum Distance Spec. AT-MC101XL and AT-MC102XL 50/125 MMF 13.00 18.70 0 2 km (1.2 mi) 62.5/125 MMF 16.80 22.50 0 2 km (1.2 mi) AT-MC103XL 9/125 SMF 16.00 19.50 0 15 km (9.4 mi) AT-MC103LH 9/125 SMF 30.00 35.00 0 40 km (24.8 mi) AT-MC103SC/FS3 and AT-MC103ST/FS3 9/125 SMF 33.00 35.00 15 km (9.4 mi) 75 km (46.
AT-MC100 Series Installation Guide Table 9 Fiber Optic Loss Specifications (Benchmarks) Fiber Type1 Fiber Optic Diameter (microns) Optical Frequency Typical Loss Factor (dB/km) Worst Case Loss Factor (dB/km) Bandwidth (Mhz-km) MMF 50/125 850 nm 3.00 3.50 400 50/125 1310 nm 1.00 1.50 400 62.5/125 850 nm 3.00 3.75 200 62.5/125 1310 nm 1.00 1.50 500 100/140 850 nm 4.00 4.00 100 9/125 1310 nm 0.40 1.00 N/A 9/125 1550 nm 0.30 0.75 N/A SMF 1.
Appendix A Translated Electrical Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Standards: This product meets the following standards. U.S. Federal Communications Commission DECLARATION OF CONFORMITY Manufacture Name: Allied Telesyn International, Corp.
AT-MC100 Series Installation Guide SAFETY !5 Laser !6 Warning Class 1 Laser product. !7 Warning Do not stare into the Laser beam. EN60825 At time of installation, the Fiber Optic Lasers comply with FDA Radiation Performance Standard 21CFR Subchapter J, applicable at date of manufacture. Use of controls or adjustments of performance or procedures other than those specified herein may result in hazardous radiation exposure.
Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. !1 Hochfrequenzstörung EN55022 Klasse B !2 Störsicherheit EN50082-1 1997 !3 ACHTUNG: Für dieses Produkt sind abgeschirmte Kabel erforderlich, damit den Richtlinien für Emission und Interferenzschutz entsprochen wird. Falls das Produkt mit nicht abgeschirmten Kabeln verwendet wird, können weitergehende Maßnahmen für die Korrektur von Interferenzproblemen auf Kosten des Benutzers notwendig werden.
AT-MC100 Series Installation Guide Standarder: Dette produkt tilfredsstiller de følgende standarder. !1 Radiofrekvens forstyrrelsesemissionEN55022 Klasse B !2 Immunitet !3 ADVARSEL: Dette produkt skal bruges med afskærmede kabler for at overholde bestemmelserne vedrørende udstråling og støjimmunitet. Hvis det bruges med uafskærmede kabler, kan det blive påkrævet af brugeren at korrigere interferensproblemer for egen regning. !4 Elektrisk sikkerhed.
Eisen: Dit product voldoet aan de volgende eisen. !1 RFI Emissie EN55022 Klasse B !2 Immuniteit EN50082-1 1997 !3 WAARSCHUWING: Om te voldoen aan de emissie- en immuniteitsnormen dient dit apparaat te zijn voorzien van afgeschermde kabels. Als het met niet-afgeschermde kabels wordt gebruikt, kan het zijn dat de gebruiker maatregelen moet treffen om interferentieproblemen voor eigen rekening op te lossen.
AT-MC100 Series Installation Guide Normes: ce produit est conforme aux normes de suivantes. !1 Emission d'interférences radioélectriques EN55022 Classe B !2 Immunité EN50082 - 1 1997 !3 AVERTISSEMENT: Il faut utiliser des câbles blindés pour ce produit afin de respecter les normes d’émission et d’immunité.
Standardit: Tämä tuote on seuraavien standardien mukainen. !1 Radioaaltojen häirintä EN55022 Luokka B !2 Kestävyys EN50082-1 1997 !3 VAROITUS: Tämä tuote vaatii suojattuja kaapeleita toimiakseen emissio- ja häiriönsietostandardien mukaisesti. Jostuotetta käytetään ilman suojattuja kaapeleita, käyttäjä voi joutua korjaamaan häirinnän aiheuttaman ongelman omallakustannuksellaan. !4 Sähköturvallisuus TUV-EN60950, UL1950, CSA 950 TURVALLISUUS !5 Laser !6 Varoitus Luokan 1 Lasertuote.
AT-MC100 Series Installation Guide Standard: Questo prodotto è conforme ai seguenti standard. !1 Emissione RFI (interferenza di radiofrequenza) EN55022 Classe B !2 Immunità EN50082-1 1997 !3 AVVERTENZA: questo prodotto, se utilizzato con cavi schermati, è conforme alle norme sulle emissioni e sull’immunità. In caso di uso senza cavi schermati, l’utente può dover adottare a proprie spese misure correttive contro le interferenze.
Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. !1 RFI stråling EN55022 Klasse B !2 Immunitet EN50082-1 1997 !3 ADVARSEL: Dette produktet må brukes med vernede kabler for å tilfredsstille emisjons- og fritakelsesstandarder. Dersom produktet brukes med uvernede kabler, må brukeren muligens rette forstyrrelsesproblemene for egen regning. !4 Elektrisk sikkerhet TUV-EN60950, UL1950, CSA 950 SIKKERHET !5 Laser !6 ADVARSEL Laserprodukt av klasse 1.
AT-MC100 Series Installation Guide Padrões: Este produto atende aos seguintes padrões. !1 Emissão De Interferência De Radiofrequência EN55022 Classe B !2 Imunidade EN50082-1 1997 !3 ADVERTÊNCIA: Este produto requer a utilização de cabos blindados para cumprimento dos standards de limites de emissão e imunidade. Se o produto for utilizado com cabos não blindados, o utilizador poderá necessitar de tomar medidas para correcção de problemas de interferência, por sua própria conta.
Estándares: Este producto cumple con los siguientes estándares. !1 Emisión RFI EN55022 Clase B !2 Inmunidad EN50082-1 1997 !3 ADVERTENCIA: Este producto exige cables protectores para ajustarse a las normas de emisión e inmunidad. Si se utiliza con cables sin protección, el usuario tendrá que correr con los gastos por las medidas a tomar en caso de problemas de interferencias. !4 Seguridad eléctrica TUV-EN60950, UL1950, CSA 950 SEGURIDAD !5 Laser !6 ¡ADVERTENCIA! Producto láser Clase 1.
AT-MC100 Series Installation Guide Standarder: Denna produkt uppfyller följande standarder. !1 Radiostörning EN55022 Klass B !2 Immunitet EN50082-1 1997 !3 VARNING! Denna produkt kräver skärmade kablar för att uppfylla standardkraven för emission och immunitet. Om den används med oskärmade kablar kan användaren vara tvungen att vidta åtgärder på egen bekostnad för att åtgärda störningsproblemet. !4 Elsäkerhet TUV-EN60950, UL1950, CSA 950 SÄKERHET !5 Laser !6 VARNING! Laserprodukt av klass 1.
Appendix B AT-MC100 Series Installation Guide Feedback Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.
Appendix C Technical Support Fax Order Name _________________________________________________________________ Company ______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province_______________________________ Zip/Postal Code ________________ Country_______________________________ Phone ______________________________ Fax_______________________________ Incident Summary Model number of Allied