User guide

Switch command reference Switching
2-17
iMG/RG Software Reference Manual (Switching)
2.2.4.1.15 SWITCH SET AGE-TIMER
Syntax SWITCH SET AGE-TIME <agetimer>
Description This command sets the value of the ageing timer, after which an un-refreshed dynamic
entry in the Forwarding Database is automatically removed.
Acceptable values are from 16 secs to 4080 secs.
To show the current switch status, use the SWITCH SHOW command.
Options The following table gives the range of values for each option that can be specified with
this command and a default value (if applicable).
Example --> switch set ageingtimer 180
See also switch show
See also SWITCH SHOW PORT
2.2.4.1.16 SWITCH SET AGING-TIME
Syntax SWITCH SET AGING-TIME { Enabled | Disabled }
Description This command enables or disables the aging time process. Once disabled all the FDB
entries already learned are kept until aging-time is re-enabled or a switch reset command
is entered.
To show the current switch status, use the SWITCH SHOW command.
Options The following table gives the range of values for each option, which can be specified with
this command, and a default value (if applicable).
Example --> switch set aging-time disabled
See also switch show
Option Description Default Value
Agetimer
Number of seconds.
(16 to 4080)
304 (secs)
Option Description Default Value
Enabled | Disabled When Enabled, the aging time process will flush
out any entry older than the age-timer value.
When Disabled, the aging time process keep all
the entries already learned. No additional entries
are learned in this status.
Enabled