2.2.4.1.1 SWITCH DIAGNOSE PORT
Syntax SWITCH DIAGNOSE PORT
Description This command executes the Time Domain Reflection test - that is used to determine
whether or not an Etherenet Cable connected to the port has a fault..
The results are whether or not there is an “open”, “short” or “good term”.for each pair.
It also prints the distance to the fault if the result is not “good term”. The accuracy is to
within approximately 10%.
Options None.
Example --> switch diagnose port lan6
Port 2 Tx: open [0ft] Rx: open [0ft]
2.2.4.1.2 SWITCH DISABLE AGEINGTIMER
Syntax SWITCH DISABLE AGEINGTIMER
Description This command stops the aging timer used by the look up engine to remove expired FDB
entries.
If the ageing timer is disabled the look up entries in the FDB are kept permanently until
the SWITCH ENABLE AGEINGTIMER command entered or the switch is reset.
To show the current switch status, use the SWITCH SHOW command.