User guide
SNMP MIB
iMG/RG Software Reference Manual (System Configuration)
1-116
1.6.10.3.1 Private traps
The following private (enterprise specific) traps are generated:
OID Max-Access Description
SYSRESTART Read-Write If set to 1 (true), this object force a
system restart. The value returned by
get requests is always 2 (false)
SYSCONFIGSAVE Read-Write If set to 1 (true) this object force a
system configuration save. The value
returned by get requests is always 2
(false)
SYSPOWERBACKUPSYSTEM Read-Only The object returns the value 1 if the
backup battery system is present oth-
erwise it returns a value of 2.
SYSPOWERBACKUPBATTERYSTATUS Read-Only The object returns the value 1 if the
battery is charged otherwise it
returns a value of 3.
SYSPOWERBACKUPPRIMARYSUPPLY Read-Only The object returns the value 1 if the
backup battery system is correctly
externally powered, otherwise it
returns a value of 2.
OID
Specific Trap
Code Description
POWERBACKPUPBATTERYON 1 This trap indicates that the external
backup power supply is disconnected.
POWERBACKPUPBATTERYMISSING 2 This trap indicates that the battery
backup system is disconnected.
POWERBACKPUPBATTERYLOW 3 This trap indicates that the battery is
low or missing.
VOIPMGCPPROTOCOLENABLETRAP 4 This trap indicates that MGCP proto-
col has been enabled.
VOIPMGCPPROTOCOLDISABLETRAP 5 This trap indicates that MGCP proto-
col has been disabled.