User guide
MIB SNMP
1-115
iMG/RG Software Reference Manual (System Configuration)
1.6.10.3 Enterprise (private) MIB
The gateway implements private objects in order to give access to specific unit configuration parameters that
are not mapped in any standard MIB.
All the private MIB objects are located under the following OID: enterprise.207.8.44.
The following private objects are available starting from software release 2-0-0:
sysInfo group
This group collects generic information about the unit
sysUsers group
This group collects the list of the users defined in the system and the login/password for each user.
sysAdmin group
This group collects basic objects used to force a unit restart, configuration saving, power status (only on AT-
RG656 models) and a special object (sysAdminCLIEntry) that acts like a shell where is possible send CLI-like
commands.
OID Max-Access Description
SYSVENDOR Read-Only The vendor company name
SYSURL Read-Only The vendor company URL
SYSMAC Read-Only The unit MAC address
SYSHARDWARE Read-Only The unit Hardware version
SYSSOFTWARE Read-Only The unit Software version
OID Max-Access Description
SYSUSERNAMER Read-Only The user name/login
SYSUSERCONFIG Read-Write The user may configure
SYSUSERACCESS Read-Write The user may configure
SYSUSERCOMMENT Read-Write Additional comment associated with this user
SYSUSERPASSWORD Read-Write The user password