User guide

Support of CWMP with TR-069 Devices Port Management (non-iMAP Devices)
5-229
AlliedView NMS Administration Guide (Controlling and Provisioning Network Devices)
Method 2
Install and run the NMS server software on a PC connected to a LAN port on the Comtrend. You must run the NMS
server software so the TFTP server is running. Run the Comtrend Boot Configurator at this PC. Do not check the Save
Only checkbox before clicking OK.
Note: The Comtrend could be connected to the NMS server that is used to manage the network. However,
since this would allow access to the network devices, this is not recommended.
5.7.6.7 Staging - Method 1
Prerequisites
The Comtrend is set to factory defaults.
A PC is connected to a LAN port on the Comtrend device. The PC obtains an IP address automatically from the
Comtrend.
1. At the NMS server, access the Comtrend Boot Configurator by going to <NMS_Home>/bin and double-clicking on
AT_CTBootConfigurator.
2. On the Comtrend Boot Configurator Form (Figure 5-204), the only fields that must be filled in are:
Mgmt. VLAN
ACS URL
Note: For a description of these and other fields, refer to Figure 5.7.6.5.
3. Check the Save Only checkbox. Click on OK.
4. Go to <NMS_Home>/tftp/Comtrend and locate the configuration file, for example ct_backupconfig.conf. Copy
the configuration file to a PC connected to a LAN port of the Comtrend.
5. At the PC connected to the Comtrend, open a web browser and go to http://192.168.1.1/ to access the Comtrend web
GUI. Log in with User Name root, and Password 12345. In the GUI sidebar, select Management > Settings > Update.
The Tools - Update Settings page opens as shown in Figure 5-211.
FIGURE 5-211 Comtrend Tools - Update Settings
6. In the Settings File Name field, enter or browse to the configuration file copied in step 4. Click Update Settings. The
Comtrend reboots (Figure 5-212). The Comtrend is now ready to be deployed