AT-GS908M AT-GS916M AT-GS924M Gigabit Ethernet Switches Installation Guide 613-001986 Rev A
Copyright © 2014 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesis, Inc.
Electrical Safety and Emissions Standards This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Translated Safety Statements Important: The indicates that a translation of the safety statement is available in a PDF document titled Translated Safety Statements posted on the Allied Telesis website at www.alliedtelesis.com/support.
Contents Preface ................................................................................................................................................................................11 Symbol Conventions .................................................................................................................................. 12 Contacting Allied Telesis............................................................................................................................
Contents 6
Figures Figure 1: AT-GS908M, AT-GS916M, and AT-GS924M Front Panels ................................................................................. Figure 2: AT-GS908M, AT-GS916M, and AT-GS924M Back Panels.................................................................................. Figure 3: STATUS LEDs...................................................................................................................................................... Figure 4: MODE LEDs ..............................
List of Figures 8
Tables Table 1. Combo Ports .........................................................................................................................................................22 Table 2. POWER LED Functional Description ....................................................................................................................23 Table 3. FAULT LED Functional Description ......................................................................................................................
List of Tables 10
Preface This guide contains the installation instructions for the AT-GS908M, ATGS916M, and AT-GS924M Gigabit Ethernet Switches.
Symbol Conventions This document uses the following conventions: Note Notes provide additional information. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data. Warning Warnings inform you that performing or omitting a specific action may result in bodily injury. Warning Warnings inform you that an eye and skin hazard exists due to the presence of a Class 1 laser device.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide Contacting Allied Telesis If you need assistance with this product, you may contact Allied Telesis technical support by going to the Support & Services section of the Allied Telesis web site at www.alliedtelesis.com/support.
Chapter 1 Overview This chapter provides descriptions of the AT-GS908M, AT-GS916M, and AT-GS924M Layer 2 Gigabit Ethernet Switches and contains the following sections: “Features” on page 16 “Front and Back Panels” on page 18 “Management Software” on page 20 “Twisted-Pair Ports” on page 21 “Combo Ports” on page 22 “LEDs” on page 23 “Reset Button” on page 28 “Mode Button” on page 29 “Power Supply” on page 30 15
Chapter 1: Overview Features Here are the hardware features of the AT-GS900M Series Gigabit Ethernet Switches. Twisted-Pair Ports SFP Slots Here are the basic features of the 10/100/1000 Mbps twisted-pair ports: 8, 16, or 24 ports per switch 10Base-TX, 100Base-T and 1000Base-T compliant IEEE 802.3u Auto-Negotiation compliant Auto-MDI/MDIX 100 meters (328 feet) maximum operating distance IEEE 802.3x Flow Control in 10/100Base-TX full-duplex operation IEEE 802.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide LEDs Installation Options The following lists the switch LEDs: Power LED; refer to “POWER LED” on page 23. Fault LED; refer to “FAULT LED” on page 24. Standby LED; refer to“STANDBY LED” on page 24. Speed and Duplex Mode LEDs; refer to “MODE LEDs” on page 24. Speed/Duplex and Link/Activity LEDs for the twisted-pair ports; refer to “Port LEDs” on page 25.
Chapter 1: Overview Front and Back Panels Figure 1 illustrates the front panels of the AT-GS908M, AT-GS916M, and AT-GS924M Gigabit Ethernet Switches.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide Figure 2 illustrates the back panels of the AT-GS908M, AT-GS916M, and AT-GS924M switches. AT-GS908M AC Input AT-GS916M AC Input AT-GS924M AC Input Figure 2.
Chapter 1: Overview Management Software The switches are shipped with the ATPro management software preinstalled. The software provides a web-browser interface for in-band, overthe-network management. In the unlikely event that the management software becomes corrupted or damaged on the switch, you can download the software from the Allied Telesis corporate web site and reinstall it on the switch. For instructions on how to install new management software, see the product documentation.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide Twisted-Pair Ports The AT-GS908M, AT-GS916M, and AT-GS924M Layer 2 Gigabit Ethernet Switches feature 8, 16, and 24 twisted-pair ports, respectively. All ports are 10Base-T, 100Base-TX, and 1000Base-TX compliant. You can set the port speeds and duplex modes either automatically with IEEE 802.3u Auto-Negotiation or manually with the management software. The twisted-pair ports feature 8-pin RJ-45 connectors.
Chapter 1: Overview Combo Ports The AT-GS916M Switch has two combo ports, and the AT-GS924M Switch has four combo ports. Each combo port consists of one 10/100/ 1000Base-T twisted-pair port and one slot for an optional 100Base-FX or 1000Base-SX/LX SFP transceiver. The twisted-pair ports are identified with the letter “R” for “Redundant” on the front faceplates of the units. The combo ports and slots are listed in Table 1. Table 1.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide LEDs There are four types of LEDs on the AT-GS900M Series switches: STATUS LEDs “STATUS LEDs” “MODE LEDs” on page 24 “Port LEDs” on page 25 “SFP Slot LEDs” on page 26 STATUS LEDs display the status of the switch. STATUS LEDs are as follows: “POWER LED” “FAULT LED” on page 24 “STANDBY LED” on page 24 The STATUS LEDs are located on the left side of the front panel of the switch. See Figure 3.
Chapter 1: Overview FAULT LED The FAULT LED reports any conditions on the switch that are not normal. Table 3 describes the states of the FAULT LED. Table 3. FAULT LED Functional Description State Off Steady Red Flashing Red Description Normal switch operation. Abnormal system operation. One of following: Firmware downloading and being written to flash memory. DC internal power operating outside the normal range. Temperature out of range.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide MODE LEDs Mode Button Figure 4. MODE LEDs Table 5 describes the MODE LEDs for the AT-GS900M Series switches. Table 5. MODE LED Functional Descriptions LED State Steady Green SPEED DUPLEX Off Steady Green Off Port LEDs Description SPEED is the selected mode. Ports display SPEED status. SPEED is not the selected mode. Ports display DUPLEX status. DUPLEX is the selected mode. Ports display DUPLEX status. DUPLEX is not the selected mode.
Chapter 1: Overview . Table 6. Port LED Functional Descriptions LED Link/Activity State Description Off The port has not established a link with a network device. On The port has established a link with a network device. Flashing Green Off If SPEED is selected by the Mode switch, the maximum operating speed of the port is 10 or 100 Mbps or link not established. Steady Green If SPEED is selected by the Mode switch, the maximum operating speed of the port is 1000 Mbps.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide . Table 7. SFP Slot LED Functional Descriptions LED Link/Activity State Description Off The port has not established a link with a network device. On The port has established a link with a network device. Flashing Green The port is transmitting or receiving network packets.
Chapter 1: Overview Reset Button Pressing the Reset button resets your switch. The Reset button is located next to the STATUS LEDs. See Figure 3 on page 23. This initiates a system reboot of the switch and reloads the current configuration file. Caution The switch does not forward network traffic during the reset process.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide Mode Button Use the Mode button to select whether the Port LEDs display the Link Activity or speed and duplex status. The Mode button is located next to the MODE LEDs. See Figure 4 on page 25.
Chapter 1: Overview Power Supply Each switch has an internal power supply with a single AC power supply socket on the back panel. To power the switch on or off, connect or disconnect the power cord provided with the switch. A power cord is supplied with the switch. Note For the power requirements, see the “Power Specifications” on page 52.
Chapter 2 Installation This chapter contains the following sections: “Reviewing Safety Precautions” on page 32 “Selecting a Site for the Switch” on page 35 “Cable Specifications” on page 36 “Unpacking the Switch” on page 37 “Installing the Power Cord Retaining Clip” on page 39 “Installing the Switch on a Desktop or Table” on page 40 “Installing the Switch in an Equipment Rack” on page 41 “Installing SFP Transceivers” on page 43 “Cabling the Switch” on page 46 “Powerin
Chapter 2: Installation Reviewing Safety Precautions Please review the following safety precautions before you begin to install the chassis or any of its components. Note The indicates that a translation of the safety statement is available in a PDF document titled Translated Safety Statements posted on the Allied Telesis website at www.alliedtelesis.com/ support. Warning To prevent electric shock, do not remove the cover. No userserviceable parts inside.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide Caution Air vents must not be blocked and must have free access to the room ambient air for cooling. E6 Warning Operating Temperature. This product is designed for a maximum ambient temperature of 50° C. E57 Note All Countries: Install product in accordance with local and National Electrical Codes.
Chapter 2: Installation Warning Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuits (for example, use of power strips).
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide Selecting a Site for the Switch Observe the following requirements when choosing a site for your switch: If you plan to install the switch in an equipment rack, verify that the rack is safely secured and will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack. If you are installing the switch on a table, verify that the table is level and secure.
Chapter 2: Installation Cable Specifications Table 8 contains the cable specifications for the twisted-pair ports. Table 8. Twisted-Pair Cabling and Distances Maximum Operating Distance Speed Type of Cable 10 Mbps Standard TIA/EIA 568-B-compliant Category 3 or better shielded or unshielded cabling with 100 ohm impedance and a frequency of 16 MHz.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide Unpacking the Switch To unpack the switch, perform the following procedure: 1. Remove all of the components from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesis. 2. Place the switch on a level, secure surface. 3.
Chapter 2: Installation AT-GS916M brackets AT-GS924M brackets Two equipment rack brackets (not included in ATGS908M package) Four or six bracket screws (not included in ATGS908M package) AT-GS916M: 4 each AT-GS924M: 6 each Retaining clip Management cable Four rubber feet (pre-installed) (for desktop installation) One regional AC power cord One, two, or four SFP slot dust covers (pre-installed). Figure 7.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide Installing the Power Cord Retaining Clip Perform the following procedure to install the power cord retaining clip on the AT-GS900M switch: 1. Locate the power cord retaining clip, as shown in Figure 8. Figure 8. Power Cord Retaining Clip 2. Install the clip on the AC power connector on the back panel of the switch.
Chapter 2: Installation Installing the Switch on a Desktop or Table You may install the switches on a desktop or table, or in a standard 19inch equipment rack. To install the switch in a rack, see “Installing the Switch in an Equipment Rack” on page 41. To place the switch on a desktop or table, perform the following procedure: 1. Remove all equipment from the package and store the packaging material in a safe place. 2.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide Installing the Switch in an Equipment Rack Note The AT-GS916M and AT-GS924M rack mounting hardware is included in the shipping package. However, the AT-GS908M rack mounting equipment must be purchased separately. The rack mounting kit model number is AT-RKMT-J05. To install the switch in a standard 19-inch equipment rack, perform the following procedure: 1.
Chapter 2: Installation 3. Mount the switch in a standard 19-inch equipment rack using four equipment rack screws (not provided with the switch). See Figure 11. Figure 11. Mounting the Switch in an Equipment Rack 4. Go to “Installing SFP Transceivers” on page 43 or skip to “Cabling the Switch” on page 46 if not installing SFP transceivers.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide Installing SFP Transceivers To install an SFP transceiver, perform the following procedure: Note The transceiver can be hot-swapped; you do not need to power off the switch to install a transceiver. However, you should always remove the cables before removing the transceiver. Note You should always install the transceiver before connecting the fiber-optic cables to it. 1.
Chapter 2: Installation 4. Slide the transceiver into the SFP slot until it clicks into place. See Figure 13. Figure 13. Inserting the SFP 5. Verify that the handle on the transceiver is in the upright position, as shown in Figure 14. This secures the transceiver and prevents it from being dislodged from the slot. SFP Transceiver Handle Figure 14. Positioning the SFP Handle in the Upright Position 6. Repeat Step 2 through Step 5 to install additional SFP transceivers.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide 7. Go to “Cabling the Switch” on page 46.
Chapter 2: Installation Cabling the Switch Observe the following guidelines when connecting twisted-pair and fiberoptic cables to the ports on the switch: 46 The connector on the cable should fit snugly into the port on the switch. The tab on the connector should lock the connector into place. Because the twisted-pair ports have auto-MDI/MDI-X, you may use straight-through twisted-pair cable to connect any type of network device to the switch.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide Powering On the Switch To power on the switch, perform the following procedure: 1. Lift up the retaining clip and insert the power cord into the AC power connector on the back of the switch, as shown in Figure 15. Figure 15. Plugging in the AC Power Cord 2. Lower the retaining clip over the AC Power Cord as shown in Figure 15. 3. Plug the other end of the power cord into a wall outlet. Warning Power cord is used as a disconnection device.
Chapter 2: Installation 4. Verify that the POWER LED is green. If the LED is OFF, see Chapter 3, “Troubleshooting” on page 49. The switch is now powered on and ready for network operations. For information on how to manage the switch, see the AT-GS900M Series CLI or Web Management Software User’s Guide.
Chapter 3 Troubleshooting This chapter contains information on how to troubleshoot the switch if a problem occurs. Note For further assistance, please contact Allied Telesis Technical Support at www.alliedtelesis.com/support. Problem 1: The POWER LED on the front of the switch is off. Solutions: The unit is not receiving power. Try the following: Verify that the power cord is securely connected to the power source and to the AC connector on the back panel of the switch.
Chapter 3: Troubleshooting Verify that you are using the appropriate category of twisted-pair cable: Category 3 or better for 10 Mbps operation and Category 5 and Category 5E for 100 and 1000 Mbps operation. Note A 1000Base connection may require 5 to 10 seconds to establish a link. Problem 3: The Link Activity LED for an SFP transceiver is off. Solutions: The fiber-optic port on the transceiver is unable to establish a link to a network device.
Appendix A Technical Specifications This appendix contains the following specifications: “Physical Specifications” “Environmental Specifications” on page 52 “Power Specifications” on page 52 “Safety and Electromagnetic Emissions Certifications” on page 52 “Connectors and Port Pinouts” on page 53 Physical Specifications Dimensions Table 9. Chassis Dimensions Model W x D x H mm (in) AT-GS908M 263 mm x 179 mm x 38 mm (10.35 in x 7.0 in x 1.5 in) AT-GS916M 341 mm x 210 mm x 44 mm (13.
Appendix A: Technical Specifications Environmental Specifications Table 11. Environmental Specifications Operating Temperature 0° C to 50° C (32° F to 122° F) Storage Temperature -20° C to 60° C (-4° F to 140° F) Operating Humidity 5% to 80% non-condensing Storage Humidity 5% to 95% non-condensing Operating Altitude Range Up to 2,000 m (6,562 ft) Power Specifications Input Supply Voltage - 100-240 VAC, 50 - 60 Hz Table 12.
AT-GS908M, AT-GS916M, and AT-GS924M Switches Installation Guide Connectors and Port Pinouts This section lists the connectors and connector pinouts. Figure 16 illustrates the pin layout for an RJ-45 connector and port. Figure 16. RJ-45 Connector and Port Pin Layout Table 14 lists the RJ-45 pin signals when a twisted-pair port is operating in the MDI configuration. Table 14.
Appendix A: Technical Specifications Table 16 lists the RJ-45 connector pins and their signals when a 1000Base-T port is operating at 1000 Mbps. Table 16.