AT-FS724L Fast Ethernet Switch Installation Guide PN 613-50464-00 Rev A
Copyright © 2003 Allied Telesyn, Inc. 960 Stewart Drive, Suite B, Sunnyvale, CA 94085, USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn, Inc.
Electrical Safety and Emission Compliance Statement Standards: This product meets the following standards. U.S. Federal Communications Commission Declaration Of Conformity Manufacturer Name: Allied Telesyn, Inc.
Electrical Safety and Emission Compliance Statement RFI Emission FCC Class B, EN55022 Class B, VCCI Class B, C-TICK 1 Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 2 Immunity EN55024 3 Electrical Safety EN60950 (TUV), UL60950 (cULus) 4 Important: Appendix B contains translated safety statements for installing this equipment.
Table of Contents Electrical Safety and Emission Compliance Statement ......................iii Table of Contents ........................................................................................... v Welcome to Allied Telesyn ......................................................................... vii Where to Find Related Guides......................................................................... vii Document Conventions ........................................................................
Table of Contents Chapter 3 Troubleshooting ........................................................................................... 19 Appendix A Technical Specifications ............................................................................ 21 Physical ............................................................................................................. 21 Environmental ..................................................................................................
Welcome to Allied Telesyn This guide contains instructions on how to install the AT-FS724L Fast Ethernet Switch. Where to Find Related Guides The Allied Telesyn web site at www.alliedtelesyn.com offers you an easy way to access the most recent documentation, software, and technical information for all of our products. For product guides, select “Support & Services” from our web site. Document Conventions This guide uses the following conventions: Note Notes provide additional information.
Welcome to Allied Telesyn Contacting Allied Telesyn This section provides Allied Telesyn contact information for technical support as well as sales or corporate information. Online Support You can request technical support online by accessing the Allied Telesyn Knowledge Base from the following web site: http://kb.alliedtelesyn.com. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
Chapter 1 Overview The AT-FS724L is Fast Ethernet switch that provides simple, cost-effective solutions for switching between 10 Mbps and 100 Mbps. The AT-FS724L switch features 24 10/100Base-TX twisted pair ports. Each twisted pair port has a RJ-45 connector and a maximum operating distance of 100 meters (328 feet). These ports are capable of Auto-Negotiating at 10 or 100 Mbps and feature half- and full-duplex operation.
Overview Key Features The AT-FS724L switch has the following key features: 24 10/100Base-TX ports System and port LEDs Auto MDI/MDI-X on all ports Auto-Negotiation on all ports (IEEE 802.3u-compliant) Store and forward switching mode Backpressure and flow control (IEEE 802.
AT-FS724L Fast Ethernet Switch Installation Guide Status LEDs Table 2 lists the status LEDs for the AT-FS724L switch. Table 2 Status LEDs LED Color Description POWER Green Power is applied to the switch. OFF No power is applied to the switch. Green A valid link has been established on the port. Blinking The port is transmitting data. OFF A link has not been detected on the port. Green The port is operating at 100 Mbps. OFF The port is operating at 10 Mbps.
Overview Duplex Mode Duplex mode refers to the way an end-node sends and receives data on the network. An end-node can operated in either half- or full-duplex mode depending on its capabilities. An end-node that is operating in half-duplex mode can either send data or receive data, but it cannot do both at the same time. An end-node that is operating in full-duplex mode can send and receive data simultaneously.
AT-FS724L Fast Ethernet Switch Installation Guide the port on the switch automatically configures itself as MDI-X. This feature allows you to use either a crossover cable or a straight-through cable when connecting a device to a twisted pair port. MAC Address Table The heart of an Ethernet switch is the Media Access Control (MAC) address table. Every device that you attach to an Ethernet network has a MAC address. This address is assigned to the device by the device’s manufacturer.
Overview This timer will delete a MAC address from the table if it does not see a frame from the end-node with the address on any port after five minutes (300 seconds). The aging timer also helps to ensure that the table is correct should an end-node be moved from one port on the switch to another port. Store and Forward These Fast Ethernet Switches use store and forward as the method for receiving and transmitting frames.
AT-FS724L Fast Ethernet Switch Installation Guide Internal Power Supply The AT-FS724L uses a universal internal switching power supply operating at 100-120/200-240V AC. The frequencies are 50/60 Hz, 0.5A at all input voltage +/-3%. Allied Telesyn ships power cords with these units to the U.S., Continental Europe, and the U.K. The switches require input of 100-120 or 200-240V AC. The AT-FS724L switch has a maximum power consumption of 15W.
Overview Network Topologies The AT-FS724L switch can be used in a variety of network topologies, such as a power workgroup or cascade. Both topologies are described below. Power Workgroup Topology A power workgroup topology, shown in Figure 2, allows each end-node to directly connect to a 10/100Base-TX port on an AT-FS724L switch. This gives each end-node a dedicated 10 Mbps or 100 Mbps link.
AT-FS724L Fast Ethernet Switch Installation Guide Cascade Topology Connecting two similar networking devices together is called ‘cascading’. Figure 3 illustrates this topology where Port 24 on the AT-FS724L switch is connected to Port 8 on the AT-FS716 switch. Since Port 24 is wired as auto MDI/MDI-X, a crossover or straight-through Category 5 or better twisted pair cable can be used.
Chapter 2 Installation Verifying the Package Contents Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative for assistance.
Installation Planning the Installation Be sure to observe the following guidelines when planning the installation of your switch. ❑ The end-nodes connected to the twisted pair port can operated at either 10 Mbps or 100 Mbps and half- or full-duplex mode. ❑ The end-node connected to a port on the switch can be a network adapter card, repeater, router, hub, or another switch. ❑ Refer to Table 3 for the cabling specifications for the twisted pair ports.
AT-FS724L Fast Ethernet Switch Installation Guide Reviewing Safety Guidelines Please review the following safety guidelines before you begin to install the switch. Warning Electrical Shock Hazard: To prevent electrical shock, do not remove the cover. There are no user-serviceable parts inside. The unit contains hazardous voltages and should only be opened by a trained and qualified technician. 5 Warning Lightning Danger: Do not work on equipment or cables during periods of lightning activity.
Installation Installing the Switch on a Table or Desktop If you are rackmounting an AT-FS724L switch, refer to “Rackmounting the Switch” on page 15. To install the switch on a table or desktop, perform the following procedure: 1. Remove all equipment from the packaging and store the packing material in a safe place. In the event a problem occurs and you need to return the unit, please use as much of the original shipping material as possible. 2. Attach the four protective feet to the bottom of the unit.
AT-FS724L Fast Ethernet Switch Installation Guide Rackmounting the Switch The AT-FS724L switch can be used on a desktop or installed in a rack. For desktop installation, refer to “Installing the Switch on a Table or Desktop” on page 14. To install an AT-FS724L in a rack, perform the following procedure: 1. If attached, remove the four protective feet from the bottom of the switch as shown in Figure 5. Figure 5 Removing the Rubber Feet 2. Remove the data cables and power cord from the switch. 3.
Installation 4. Secure the switch to the rack using 2 screws (not provided) for each side as shown in Figure 7. Figure 7 Installing the Switch to the Rack 5. Apply power to the switch by plugging one end of the power cord to the power receptacle and the other end to a power outlet. Verify that the POWER LED is green. If the LED is OFF, refer to “Troubleshooting” on page 19. Note The switch performs a self-diagnostic test upon power up. This takes about 20 seconds to complete. 6.
AT-FS724L Fast Ethernet Switch Installation Guide Warranty Registration When you finish installing the product, you should register you product by completing the enclosed warranty card and sending it in.
Chapter 3 Troubleshooting Follow the guidelines below to test and troubleshoot the installation in the event a problem occurs. If the POWER LED is OFF, do the following: For an external power supply, check to be sure that the power adapter is securely connected to a power outlet and that the power adapter cable is securely connected to the back of the switch.
Appendix A Technical Specifications Physical Dimensions: WxDxH 11.6 in x 7.8 in x 1.72 in) Weight: 2.5 kg (5.
Technical Specifications Electrical Rating Internal Universal Power Supply: 100 - 240 V AC, 50/60 Hz, 0.
AT-FS724L Fast Ethernet Switch Installation Guide Pinout Assignments Figure 8 shows the pin assignments of the RJ-45 connector. 8 1 8 1 Figure 8 RJ-45 Connector Table 4 lists the 100Base-TX connector pins and their signals when the port is operating in either MDI or MDI-X configuration.
Appendix A Translated Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Translated Safety and Emission Information Standards: This product meets the following standards: U.S. Federal Communications Commission Declaration Of Conformity Manufacturer Name: Allied Telesyn, Inc. Manufacturer Address: 960 Stewart Drive, Suite B Sunnyvale, CA 94085, USA Manufacturer Telephone: 408-730-0950 Declares that the product: Fast Ethernet Switches Model Numbers: AT-FS724L This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules.
AT-FS724L Fast Ethernet Switch Installation Guide 1 RFI Emission 2 Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 3 Immunity EN55024 4 Electrical Safety EN60950 (TUV), UL60950 (cULus) 5 Electrical Notices Warning: ELECTRIC SHOCK HAZARD To prevent ELECTRIC shock, do not remove the cover. No user-serviceable parts inside.
Translated Safety and Emission Information Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. 1 Hochfrequenzstörung 2 Warnung: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen. 3 Störsicherheit EN55024 4 Elektrische Sicherheit EN60950 (TUV), UL60950 (cULus) 5 Achtung: GEFÄHRLICHE SPANNUNG Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer wartbaren Teile.
AT-FS724L Fast Ethernet Switch Installation Guide Standarder: Dette produkt tilfredsstiller de følgende standarder. 1 Radiofrekvens forstyrrelsesemission FCC Klasse B, EN55022 Klasse B, VCCI Klasse B, C-TICK 2 Advarsel: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
Translated Safety and Emission Information Eisen: Dit product voldoet aan de volgende eisen. 1 RFI Emissie 2 Waarschuwing: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen. 3 Immuniteit EN55024 4 Electrische Veiligheid EN60950 (TUV), UL60950 (cULus) 5 Elektriske Forholdsregler Advarsel: RISIKO FOR ELEKTRISK STØD For at forebygge ELEKTRISK stød, undlad at åbne apparatet.
AT-FS724L Fast Ethernet Switch Installation Guide Normes: Ce produit est conforme aux normes de suivantes. 1 Emission d'interférences radioélectriques FCC Classe B, EN55022 Classe B, VCCI Classe B, C-TICK 2 Mise En Garde: Dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l'utilisateur devra prendre les mesures adéquates.
Translated Safety and Emission Information Standardit: Tämä tuote on seuraavien standardien mukainen. 1 Radioaaltojen häirintä 2 Varoitus: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. 3 Kestävyys EN55024 4 Sähköturvallisuus EN60950 (TUV), UL60950 (cULus) 5 Sähköön Liittyviä Huomautuksia Varoitus: SÄHKÖISKUVAARA Estääksesi SÄHKÖISKUN älä poista kantta.
AT-FS724L Fast Ethernet Switch Installation Guide Standard: Questo prodotto è conforme ai seguenti standard. 1 Emissione RFI (interferenza di radiofrequenza) FCC Classe B, EN55022 Classe B, VCCI Classe B, C-TICK 2 Avvertenza: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all'utente di prendere gli adeguati provvedimenti.
Translated Safety and Emission Information Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. 1 RFI stråling 2 Advarsel: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. 3 Immunitet EN55024 4 Elektrisk sikkerhet EN60950 (TUV), UL60950 (cULus) 5 Elektrisitet Advarsel: FARE FOR ELEKTRISK SJOKK For å unngå ELEKTRISK sjokk, må dekslet ikke tas av.
AT-FS724L Fast Ethernet Switch Installation Guide Padrões: Este produto atende aos seguintes padrões. 1 Emissão De Interferência De Radiofrequência FCC Classe B, EN55022 Classe B, VCCI Classe B, C-TICK 2 Aviso: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
Translated Safety and Emission Information Estándares: Este producto cumple con los siguientes estándares. 1 Emisión RFI 2 Advertencia: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
AT-FS724L Fast Ethernet Switch Installation Guide Standarder: Denna produkt uppfyller följande standarder. 1 Radiostörning 2 Varning: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder.