AT-FS7016 AT-FS7024 Fast Ethernet Smart Switches Installation Guide PN 613-50469-00 Rev A
Copyright 2003 Allied Telesyn, Inc. 960 Stewart Drive Suite B, Sunnyvale, CA 94085, USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn, Inc.
Electrical Safety and Emissions Compliance Statement Standards: This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Electrical Safety and Emissions Compliance Statement Tärkeää: Liite B sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet. Kun näet -symbolin, katso käännettyä turvaohjetta liitteestä B. Importante: l’Appendice B contiene avvisi di sicurezza tradotti per l’installazione di questa apparecchiatura. Il simbolo , indica di consultare l’Appendice B per l’avviso di sicurezza nella propria lingua. Viktig: Tillegg B inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret.
Table of Contents Electrical Safety and Emissions Compliance Statement ....................iii Welcome to Allied Telesyn ......................................................................... vii Where to Find Web-based Guides ................................................................... vii Document Conventions ...................................................................................viii Contacting Allied Telesyn ..........................................................................
Table of Contents Chapter 3 Troubleshooting ........................................................................................... 21 Appendix A Technical Specifications ............................................................................ 23 Physical ............................................................................................................. 23 Environmental ..................................................................................................
Welcome to Allied Telesyn This guide contains instructions on how to install the AT-FS0716 and AT-FS0724 Fast Ethernet Smart Switches. Where to Find Web-based Guides The user guides for all Allied Telesyn products are available in Portable Document Format (PDF) from the Allied Telesyn web site at www.alliedtelesyn.com. You can view the documents online or download them onto a local workstation or server.
Welcome to Allied Telesyn Document Conventions This guide uses the following conventions: Note Notes provide additional information. Caution Cautions informs you that performing or omitting a specific action may result in equipment damage or loss of data. Warning Warnings informs you that performing or omitting a specific action may result in bodily injury. Contacting Allied Telesyn This section provides Allied Telesyn contact information for technical support as well as sales or corporate information.
AT-FS7016 and AT-FS0724 Installation Guide For Sales or Corporate Information You can contact Allied Telesyn for sales or corporate information at our web site: www.alliedtelesyn.com. To find the contact information for your country, select “Contact Us” then “Worldwide Contacts”. Obtaining Management Software Updates New releases of management software for our managed products can be downloaded from either of the following Internet sites: ❑ Allied Telesyn web site: http://www.alliedtelesyn.
Chapter 1 Overview The AT-FS7016 and AT-FS7024 are Layer 2, Fast Ethernet Smart Switches. These switches offer a range of features and capabilities, including limited management that simplifies the task of creating or expanding an Ethernet or Fast Ethernet network. A Fast Ethernet Smart Switch can be used in a network environment which requires some configuration and minimum maintenance and monitoring. The AT-FS7016 switch features 16 10/100Base-TX twisted pair ports.
Overview Figure 2 illustrates the front panel of the AT-FS7024 switch. 10/100Base-TX Twisted Pair Ports AT-FS7024 24 Port Fast Ethernet Smart Switch RS-232 TERMINAL PORT POWER AUTO MDI / MDI-X LINK/ACT 100M FDX 1 2 3 RS-232 Terminal Port 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Status LEDs Figure 2 AT-FS7024 Front Panel Figure 3 illustrates the back panel of the AT-FS7016 and AT-FS7024 switches.
AT-FS7016 and AT-FS7024 Installation Guide Table 1 lists the number of ports, connector type, and maximum operating distance for each smart switch.
Overview Status LEDs Table 2 lists the status LEDs for the AT-FS7016 and AT-FS7024 switches. Table 2 Status LEDs LED Color Description POWER Green Power is applied to the switch. LINK/ACT Green A valid link has been established on the port. Blinking The port is transmitting data. OFF A link has not been detected on the port. Green The port is operating at 100 Mbps. OFF The port is operating at 10 Mbps. Green The port is operating in full-duplex mode.
AT-FS7016 and AT-FS7024 Installation Guide Port Speed The twisted pair ports are 10/100Base-TX compliant and are capable of both 10 Mbps and 100 Mbps speeds. You can set the port speed manually or, since the ports are IEEE 802.3 Auto-negotiation compliant, you can let the switch set each port’s speed automatically. With Auto-negotiation, the switch automatically matches the highest possible common speed between the port on the switch and the port on the end-node.
Overview Auto MDI/MDI-X An RJ-45 twisted pair port on a 10 Mbps or 100 Mbps Ethernet network device can have one of two possible wiring configurations: MDI or MDI-X. The RJ-45 port on a PC, router, or bridge is typically wired as MDI, while the twisted pair port on a switch or hub is usually MDI-X. To connect two 10 Mbps or 100 Mbps network devices together that have dissimilar port wiring configurations, such as MDI to MDI-X, you would use a straight-through twisted pair cable.
AT-FS7016 and AT-FS7024 Installation Guide Note These default settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulation program. Power Requirements The AT-FS7016 and AT-FS7024 switches use a universal internal switching power supply. Allied Telesyn ships power cords with these units to the U.S., Continental Europe, and the U.K. The AT-FS7016 switch requires input of 100 - 240 V AC, 0.8A, 50/60 Hz. The AT-FS7024 switch requires input of 100 - 240 V AC, 0.5A, 50/60 Hz.
Overview Network Topologies The AT-FS7016 and AT-FS7024 Fast Ethernet Smart Switches can be used in a variety of network topologies. Three types of topologies are described below. Power Workgroup Topology A power workgroup topology, shown in Figure 4, allows each end-node to directly connect to a 10/100Base-TX twisted pair port on an AT-FS7016 switch. This gives each end-node a dedicated 10 Mbps or 100 Mbps link.
AT-FS7016 and AT-FS7024 Installation Guide Collapsed Topology In the topology illustrated in Figure 5, an AT-FS7016 switch connects together 10/100 Mbps Ethernet hubs. This type of topology is often referred to as a collapsed backbone topology. The switch functions as the focal point of the network by acting as a bridge between the different workgroups.
Overview Mixed Topology Figure 6 illustrates a network of three AT-FS7024 switches. The workstations and servers are connected either directly to a switch or indirectly through an Ethernet hub. The switches are connected together through 10/100Base-TX twisted pair ports.
Chapter 2 Installation Verifying the Package Contents Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative for assistance. ❑ One AT-FS7016 or AT-FS7024 Fast Ethernet Smart Switch ❑ Four protective feet (AT-FS7016 only) ❑ AC power cord (for U.S., Continental Europe, or U.K.
Installation Planning the Installation Be sure to observe the following guidelines when planning the installation of your switch. ❑ The end-nodes connected to the twisted pair ports can operate at either 10 Mbps or 100 Mbps and half- or full-duplex mode. Refer to “Port Speed” and “Duplex Mode” on page 5 for additional information. ❑ An end-node connected to a port on the switch can be a network adapter card, repeater, router, hub, or another switch.
AT-FS7016 and AT-FS7024 Installation Guide Selecting a Site Be sure to observe the following guidelines when selecting a site for your switch. ❑ Select a site that is dust-free and moisture-free. ❑ Select a site that will allow you to easily access the switch’s power and data cables. ❑ The twisted pair port cabling must be kept away from sources of electrical noise, such as radios, transmitters, power lines, broadband amplifiers electrical motors, and fluorescent fixtures.
Installation Reviewing Safety Guidelines Please review the following safety guidelines before you begin to install the switch. Warning Electrical Shock Hazard: To prevent electrical shock, do not remove the cover. There are no user-serviceable parts inside. The unit contains hazardous voltages and should only be opened by a trained and qualified technician. 5 Warning Lightning Danger: Do not work on equipment or cables during periods of lightning activity.
AT-FS7016 and AT-FS7024 Installation Guide Installing the Switch on a Table or Desktop If you are rackmounting an AT-FS7016 or AT-FS7024 switch, refer to “Rackmounting the Switch” on page 17. To install the switch on a table or desktop, perform the following procedure: 1. Remove all equipment from the packaging and store the packing material in a safe place. In the event a problem occurs and you need to return the unit, please use as much of the original shipping material as possible. 2.
Installation ❑ Since the ports on the switch are auto MDI/MDI-X, you can use either a straight-through or crossover twisted pair cable to connect any type of network device to a port on the switch. Refer to “Auto MDI/MDI-X” on page 6 for additional information. ❑ If you are creating a port trunk, do not connect the cable of the trunk to the switch until you have configured the trunk using the management software.
AT-FS7016 and AT-FS7024 Installation Guide Rackmounting the Switch The AT-FS7016 and AT-FS7024 switches can be used on a desktop or installed in a rack. For desktop installation, refer to “Installing the Switch on a Table or Desktop” on page 15. To install the switch in a rack, perform the following procedure: 1. If attached, remove the four protective rubber feet from the bottom on the unit. ❑ For the AT-FS7016 switch, remove the protective feet from the bottom of the unit, as shown in Figure 8.
Installation 2. Attach the rackmounting brackets to each side of the switch using the screws provided. See Figure 10. Figure 10 Attaching the Rackmounting Brackets to the Switch 3. Secure the switch to the rack using two screws (not provided) for each side, as shown in Figure 11. Figure 11 Installing the Switch to the Rack 4. Apply power to the switch by plugging the AC power cord into an AC power outlet; then plug the other end of the power cord into the receptacle located on the back of the switch. 5.
AT-FS7016 and AT-FS7024 Installation Guide Note The switch performs a self-diagnostic test upon power up. This takes about 20 seconds to complete. 6. Connect the twisted pair cables to a twisted pair ports on the switch and on the end-nodes. When connecting a twisted pair cable to a port on the switch, observe the following: ❑ An RJ-45 connector should fit snugly into the port on the switch. The tab on the connector should lock in connector into place.
Chapter 3 Troubleshooting Follow the guidelines below to test and troubleshoot the installation in the event a problem occurs. If the POWER LED is OFF, do the following: Check to be sure that the power cord is securely connected to a power outlet and that the other end of the power cord is securely connected to the back of the switch. Check that the voltage from the power source is within the required levels for your region.
Troubleshooting If you are unable to establish a local management session with the switch through the RS-232 terminal port, do the following: Check to be sure that the RS-232 cable is securely connected to the RS-232 terminal port on the switch and to the RS-232 port on the terminal or PC. Check to be sure that you are using a straight-through RS-232 cable. Do not use a cross-over cable.
Appendix A Technical Specifications Physical Dimensions: WxDxH AT-FS7016 330 mm x 155 mm x 44 mm (13.0 in x 6.1 in x 1.73 in) AT-FS7024 440 mm x 174 mm x 41 mm (17.32 in x 6.85 in x 1.61 in) Weight: AT-FS7016 1.5 kg (3.30 lb) AT-FS7024 2.26 kg (4.
Technical Specifications Electrical Rating Internal Universal Power Supply: Input AT-FS7016 100 - 240 V AC, 0.8A, 50/60 Hz AT-FS7924 100 - 240 V AC, 0.
AT-FS7016 and AT-FS0724 Installation Guide Pinout Assignments Figure 12 shows the pin assignments of the RJ-45 connector. Pin 8 Pin 1 Figure 12 RJ-45 Connector Table 4 lists the 10/100Base-TX connector pins and their signals when the port is operating in either MDI or MDI-X configuration.
Appendix B Translated Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Translated Safety and Emission Information Standards: This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AT-FS7016 and AT-FS7024 Installation Guide Electrical—Auto Voltage Adjustment This product will automatically adjust to any voltage between the ranges shown on the label. 9 Electrical—Type Class 1 Equipment THIS EQUIPMENT MUST BE EARTHED. Power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
Translated Safety and Emission Information 11 Betriebstemperatur: Dieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr als 40° C entworfen. 12 Alle Länder: Installation muß örtlichen und nationalen elektrischen Vorschriften entsprechen. Standarder: Dette produkt opfylder følgende sikkerhedsstandarder. 1 Radiofrekvens forstyrrelsesemission 2 Advarsel: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse.
AT-FS7016 and AT-FS7024 Installation Guide Normen: Dit product voldoet aan de volgende veiligheidsnormen. 1 RFI Emissie 2 Waarschuwing: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de. 3 Immuniteit EN55024 4 Electrische Veiligheid TUV-EN60950, UL60950 (cULus) EN55022 Klasse A Veiligheid 5 Waarschuwingen Met Betrekking Tot Elektriciteit Waarschuwing: GEVAAR VOOR ELEKTRISCHE SCHOKKEN Verwijder het deksel niet, teneinde ELEKTRISCHE schokken te voorkomen.
Translated Safety and Emission Information Normes: ce produit est conforme aux normes de sécurité suivantes. 1 Emission d’interférences radioélectriquesEN55022 Classe A 2 Mise En Garde: dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates.
AT-FS7016 and AT-FS7024 Installation Guide Normit: Tämä tuote on seuraavien turvallisuusnormien mukainen. 1 Radioaaltojen häirintä 2 Varoitus: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin.
Translated Safety and Emission Information Standard: questo prodotto soddisfa i seguenti standard di sicurezza. 1 Emissione RFI (interferenza di radiofrequenza) EN55022 Classe A 2 Avvertenza: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti.
AT-FS7016 and AT-FS7024 Installation Guide Sikkerhetskrav: Dette produktet oppfyller følgende sikkerhetskrav. 1 RFI stråling 2 Advarsel: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. 3 Immunitet EN55024 4 Elektrisk sikkerhet TUV-EN60950, UL60950 (cULus) EN55022 Klasse A Sikkerhet 5 Elektrisitet Advarsel: FARE FOR ELEKTRISK SJOKK For å unngå ELEKTRISK sjokk, må dekslet ikke tas av.
Translated Safety and Emission Information Padrões: Este produto satisfaz os seguintes padrões de segurança. 1 Emissão de interferência de radiofrequência 2 Aviso: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
AT-FS7016 and AT-FS7024 Installation Guide Normas: este producto cumple con las siguientes normas de seguridad. 1 Emisión RFI 2 Advertencia: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
Translated Safety and Emission Information Normer: Denna produkt uppfyller följande säkerhetsnormer. 1 Radiostörning 2 Varning: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. 3 Immunitet EN55024 4 Elsäkerhet TUV-EN60950, UL60950 (cULus) 5 Tillkännagivanden Beträffande Elektricitetsrisk: RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt, ta ej av locket. Det finns inga delar inuti som behöver underhållas.