AT-FH708E Dual Speed Mini Hub Installation Guide PN 613-10758-00 Rev B
Copyright 1998 Allied Telesyn International, Corp. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp.
FCC Compliance Statement Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in residential installation. This equipment generated, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications.
Table of Contents FCC Compliance Statement ....................................................................................................................................................... iii Notice ................................................................................................................................................................................... iii CE Mark Declaration of Conformance ......................................................................................
Table of Contents Appendix B Technical Support Fax Order ....................................................................................................................................................17 Incident Summary ......................................................................................................................................................................17 Appendix C AT-FH708E Hub Installation Guide Feedback ...............................................................
Chapter 1 Product Description The AT-FH708E Mini Hub is an 8-port 10/100Mbps dual speed hub that offers a cost-effective solution to today’s growing need of network speed integration. With eight 10/100Mbps plug-and-play dual speed ports equipped in its compact body, it is possible to achieve the coexistence of 10Mbps and 100Mbps devices in a single network now and step to 100Mbps network in the future.
Package Contents Package Contents The package should include the following items: ❑ One 8-port Dual Speed Mini Hub ❑ One power adapter ❑ This Installation Guide If any item is missing, please contact your dealer immediately. Front Panel The front panel consists of the following: ❑ LEDs ❑ Uplink Switch (port 8) The LEDs help monitor the hub’s operating status and overall network performance. See Table 1 for further information concerning the LEDs.
AT-FH708E Hub Installation Guide LEDs Table 1 lists and describes the LEDs.
Rear Panel Rear Panel The rear panel has one power connector, which accepts 5V 2.5A power input, and DIP switches for manual speed setting and eight RJ45 ports. DIP Switches for Port 7 and Port 8 Port 8 Port 7 5V 2.5A 1 2 3 4 Auto 100M 10M 8 7 6 5 4 3 2 1 Eight RJ45 Ports Auto-negotiate Switch 100M Switch 10M Switch Power Connector Figure 3 AT-FH803E Rear Panel DIP Switches Table 2 and Table 3 list the DIP switch settings for Port 8 and Port 7.
Chapter 2 Installation Installing the Mini Hub 1. Place the Hub on a smooth and horizontal surface. 2. Establish network connection by plugging one end of the Category 5 UTP/STP cable RJ45 connector into the hub port, the other end to the Ethernet/Fast Ethernet adapter installed in the workstation computers. 3. If necessary, adjust port speed by setting the DIP switches before connecting network devices. 4. Connect each device by repeating Step 2 and 3. 5. Make sure that each device is connected properly.
Application Application The hub can be deployed where 10Mbps and 100Mbps network devices coexist and need to be integrated. Figure 4 illustrates a sample application.
AT-FH708E Hub Installation Guide Technical Specifications Standard IEEE802.3 (10Base-T) & IEEE802.
Chapter 3 Troubleshooting This chapter describes the procedures to test and troubleshoot the hub. Connectivity Testing In the following procedure, you will test each port for a valid connection and to confirm the correct operation of the network. 1. Start with Ports 1 and 2. Connect these two ports of a single hub to two nodes or workstations and turn on the hub’s power supply. 2. Make sure the Link/Activity and other LEDs of both hub ports are lit. 3.
Problem Solving Problem Solving Is the unit receiving power? Check the POWER LED on the front of the hub. This green LED should be lit. If the power LED is not on: 1. Check the back of the unit. Make sure the power cord is attached securely. 2. Check the AC power adapter. Make sure the power adapter is plugged into a functioning wall outlet and that it is properly inserted into the hub’s power connector on the back of the unit.
AT-FH708E Hub Installation Guide 4. Problem 4: There is data loss between the hub and one of the attached network nodes. ❑ Solution 4: — Make sure that the cable length between the hub and the connected network device is no greater than 100 meters. — Make sure you are using Category 5 cable.
Appendix A Hub Specifications Physical Characteristics Chassis Dimensions: 6.0 in. (153 mm) (L) x 6.6 in. (169 mm) (W) x 1.8 in. (3 mm) (H) Weight: 2 lbs. 12 oz (1.25 kg.) Operating temperatures: 0° to 40° C (32o F to 104o F) Storage temperatures: -20° to 70° C (-4° F to 158° F) Relative humidity: 10% to 90% (operating) 5% to 90% (storage) Operating altitude: Up to 10,000 ft (3,048 m) Standard: IEEE 802.3 10Base-T Ethernet IEEE 802.
Cabling Specifications Cabling Specifications Category 5 UTP/STP for 100 Mbps; Category 3, 4, or 5 UTP for 10 Mbps Maximum of 100 meters between hub and network node Electrical Specifications Power: External power supply with 100 to 120 VAC or 200 to 240 VAC, 50/60 Hz input. UTP (RJ45) Connector Figure 5 shows an RJ45 connector. For a 100Base-TX link between switches, —any two Medium Attachment Units (MAUs)—you need a crossover cable.
AT-FH708E Hub Installation Guide 100Base-TX Cable There are various grades of voice-quality and data-quality cables available. These can appear to be similar externally, although their highspeed data transmission characteristics are radically different. The identification problem is made worse by some suppliers selling voice-quality cables as data-quality cables. If voice-quality cables are used in a 100Base-TX network system, data movement may be slow, collision-prone or non-existent.
Appendix B Technical Support Fax Order Name__________________________________________________________________________________ Company ______________________________________________________________________________ Address _______________________________________________________________________________ City ___________________________ State/Province____________________________________________ Zip/Postal Code _____________________ Country____________________________________________ Phone _____________________
Appendix C AT-FH708E Hub Installation Guide Feedback Please tell us what additional information you would like to see discussed in the guide. If there are topics you would like information on that were not covered in the guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn International, Corp. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of the guide.
Appendix D Where To Find Us For Technical Support or Service Location Phone Fax Americas United States, Canada, Mexico, Central America, South America 1 (800) 428-4835 1 (918) 628-3222 Asia Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India (+65) 3815-613 (+65) 3833-830 Australia Australia, New Zealand (+61) 2-9438-5111 (+61) 2-9438-4966 France France, Belgium, Luxembourg, The Netherlands, Middle East, Africa (+33) 1-60-92-15-32 (+33) 1-69-28-37-49 Germany Ger