AT-FS705E FC AT-FS706E FC 10/100 Mbps Ethernet Switches Installation Guide PN 613-50221-00 Rev A
Copyright 2001 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94085, USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp.
Electrical Safety and Emission Compliance Statement Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Importante: El Apéndice A contiene mensajes de seguridad traducidos para la instalación de este equipo. , vaya al Apéndice A para ver el mensaje de seguridad traducido a su idioma. Cuando vea el símbolo Obs! Bilaga A innehåller översatta säkerhetsmeddelanden avseende installationen av denna utrustning. När du ser , skall du gå till Bilaga A för att läsa det översatta säkerhetsmeddelandet på ditt språk.
Table of Contents Electrical Safety and Emission Compliance Statement .......................iii Welcome to Allied Telesyn .......................................................................... vii Where to Find Web-based Guides ................................................................... vii Document Conventions .................................................................................... vii Contacting Allied Telesyn ......................................................................
Chapter 2 Installing the Switch .................................................................................... 17 Reviewing Safety Guidelines ........................................................................... 17 Verifying the Package Contents ...................................................................... 18 Selecting a Site for the Switch ......................................................................... 19 Installing the Twisted Pair and Fiber Optic Cabling ...................
Welcome to Allied Telesyn The guide contains instructions on how to install the AT-FS705E FC Series and AT-FS706E FC Series Ethernet Switches. Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com contains the most recent documentation for all of our products. All product guides can be downloaded from the web site in PDF format. Document Conventions This guide uses several conventions that you should become familiar with before you begin to install the product.
Contacting Allied Telesyn You can contact Allied Telesyn technical support by telephone, fax, or e-mail. You can also contact technical support online through our web site. Online Support You can request technical support online by filling out the Online Technical Support Form at www.alliedtelesyn.com/support/supportf.asp or by accessing the Technical Support Knowledge Base from the Allied Telesyn North American web site.
AT-FH705E FC and AT-FS706E FC Installation Guide E-mail Support United States and Canada TS1@alliedtelesyn.com Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands latin_america@alliedtelesyn.com Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
FTP Server If you need a new version of management software for an Allied Telesyn managed device and you know the file name of the program, you can download the software by connecting directly to our FTP server at ftp:// gateway.centre.com. At login, enter ‘anonymous’ as the username and your e-mail address as the password. For Sales or Corporate Information Allied Telesyn International, Corp.
Chapter 1 Overview The AT-FS705E FC Series and the AT-FS706E FC Series Fast Ethernet switches are unmanaged Layer 2 switches. They can be used in a variety of network configurations and topologies. You can use the switches to create small workgroups with dedicated 10/100 Mbps links to your network devices, such as workstations, servers, printers, and routers. You can also use the switches to interconnect Ethernet hubs to provide a bridge between the different workgroups of your network.
Figure 1 and Figure 2 illustrate the front and rear panels of the AT-FS705E FC Series and AT-FS706E FC Series Ethernet switches, respectively. Fiber Optic Twisted Pair Port LEDS Port LEDs Fiber Optic Port Duplex Mode Switch 10/100TX 100FX Allied Telesyn AT-FS705E FC/SC LNK/ACT LNK/ACT HALF 10BASE-T / 100BASE-TX 4 PORT ETHERNET SWITCH WITH 100FX UPLINK Power LED 100M FULL FD 5 100FX DUPLEX 1 2 3 TX 4 10Base-T/100Base-TX Ports 5 5 4 3 2 1 PWR DC In 3.
AT-FS705E FC and AT-FS706E FC Installation Guide 10/100 Mbps Twisted Pair Ports The AT-FS705E FC and AT-FS706E FC switches have four twisted pair ports. Type of Connector The twisted pair ports have RJ45 connectors. Speed These ports are compliant with the 10Base-T and 100Base-TX standards and are capable of either 10 Mbps or 100 Mbps operation. The ports are IEEE 802.
Maximum Distance The maximum distance of a twisted pair cable is 100 meters (328 feet). Cable lengths that exceed this limit can result in poor or erratic network performance. Auto MDI/MDI-X An RJ45 twisted pair port on a 10 Mbps or 100 Mbps Ethernet network device can be wired as either MDI and MDI-X. Twisted pair ports on personal computers, routers, and bridges are typically wired as MDI. The twisted pair ports on switches and hubs are usually MDI-X.
AT-FS705E FC and AT-FS706E FC Installation Guide 100 Mbps Fiber Optic Port The AT-FS705E FC and AT-FS706E FC Ethernet switches feature one and two fiber optic ports, respectively. You can use the fiber optic ports to connect the switch to other switches or other end nodes over large distances. Type of Connector The AT-FS705E FC Series and the AT-FS706E FC Series switches come with a variety of fiber optic connectors.
Maximum Distance The maximum operating distance of the fiber optic ports on the AT-FS705E FC and AT-FS706E FC Ethernet switches is 2 kilometers (1.25 miles). Cable lengths that exceed this limit can result in poor or erratic network performance. Note The fiber optic port on the network device that you intend to connect to the AT-FS705E FC or AT-FS706E FC Ethernet switch must have the same operating characteristics as the fiber optic port on the switch.
AT-FS705E FC and AT-FS706E FC Installation Guide Introduction to Ethernet Switching An Ethernet switch is designed to manage the flow of data between the various devices that are connected to its ports. MAC Address Table The heart of an Ethernet switch is the Media Access Control (MAC) address table. Every device that you attach to an Ethernet network has a MAC address. This address is assigned to the device by the device’s manufacturer.
The MAC address table in the AT-FS705E FC Series and AT-FS706E FC Series switches can store up to 4,000 MAC addresses. To prevent the table from becoming filled with addresses of end nodes that are no longer active, the switch has a MAC address aging timer. This timer will delete a MAC address from the table if it does not see a frame from the end node with the address on any port after five minutes (300 seconds).
AT-FS705E FC and AT-FS706E FC Installation Guide How a switch signals an end node to stop transmitting data differs depending on the speed of the end node and switch port. Ports operating at 10 Mbps use flow control while ports operating at 100 Mbps use backpressure. For a 10 Mbps port, the switch will stop an end node from transmitting data by forcing a collision. A collision on an Ethernet network occurs when two nodes attempt to transmit data using the same data link at the same time.
System LEDs The switch has a series of LEDs that you can use to determine the operating status of the system and the ports. The LEDs are described in Table 1. Table 1 System and Port LEDs LED Color Function PWR Steady Green The switch is receiving power. FD Steady Green The fiber optic port is operating in full-duplex mode. OFF The fiber optic port is operating in half-duplex mode. Steady Green The twisted pair port is operating at 100 Mbps. OFF The twisted pair port is operating at 10 Mbps.
AT-FS705E FC and AT-FS706E FC Installation Guide Network Topologies There are a variety of network topologies that you can create with the AT-FS705E FC and AT-FS705E FC Series switches. The first topology shown in Figure 3 is of a power workgroup. Each end node is connected directly to a port on an AT-FS705E FC switch, giving each node a dedicated 10 Mbps or 100 Mbps link. AT-FS705E FC 1 2 4 TX 5 RX DC In 3.
In the topology illustrated in Figure 4, an AT-FS705E FC is used to connect together four 10/100 Mbps Ethernet hubs. Here the switch functions as a bridge between the different workgroups by controlling the flow of data between the workgroups. The switch transfers an Ethernet frame from hub to hub only when the destination node for the frame is on a different hub than the node that originated the frame. This reduces the amount of unnecessary data traffic in each workgroup.
AT-FS705E FC and AT-FS706E FC Installation Guide If your network consists of several AT-FS705E FC and AT-FS706E FC switches, then you will probably want to connect them together to form an integrated network. Here the fiber optic ports can be extremely useful. You can use the ports to create a fiber optic backbone. With a maximum operating distance of 2 kilometers (1.25 miles), the ports can be used to connect together switches that are physically far apart.
If you have more than three AT-FS705E FC or AT-FS706E FC switches that you want to connect together, then you might use an 100Base Ethernet switch that has multiple fiber optic ports to act as a backbone switch. This switch will function as the connection focal point for all the AT-FS705E FC and ATFS706E FC switches in your network. This is often referred to as a collapsed backbone. An example of this topology is illustrated in Figure 6.
AT-FS705E FC and AT-FS706E FC Installation Guide In designing a network topology, be sure your topology does not contain any loops. A loop exists when there is more than one path between any two end nodes in your network. A loop can result in what is referred to as broadcast storms, where Ethernet frames become caught in repeating cycles that needlessly consume network bandwidth. This often results in poor network performance. An example of an invalid loop topology is shown in Figure 7.
Chapter 2 Installing the Switch This chapter contains the installation instructions for the AT-FS705E FC and AT-706E FC Ethernet switches. Reviewing Safety Guidelines Please review the following safety guidelines before you begin to install the Ethernet switch. Warning Class 1 laser product. 5 Warning Do not stare into the laser beam. 6 Warning Electric Shock Hazard: To prevent electric shock, do not remove the cover. There are no user-serviceable parts inside.
Caution Pluggable Equipment: The socket outlet should be installed near the equipment and should be easily accessible. 10 Caution Air vents: The air vents must not be blocked on the unit and must have free access to the room ambient air for cooling. 11 Caution Operating Temperature: This product is designed for a maximum ambient temperature of 40°C. 12 Caution All Countries: Install this product in accordance with local and National Electric Codes.
AT-FS705E FC and AT-FS706E FC Installation Guide Selecting a Site for the Switch Be sure to observe the following requirements when choosing a site for your switch: G G G G G G G Make sure that the switch’s power is accessible and cables can be easily connected. Air flow around the switch and through its vents on the side and rear must not be restricted. If you are installing the switch on a desk, make sure it is placed on a level, secure desktop. Do not place objects on top of the switch.
Installing the Switch On a Table or Desktop To install the switch on a table or desktop, perform the following procedure: 1. Remove all components from the shipping package and store the packaging material in a safe location. 2. Locate a level, secure surface for the switch. Note If desired, you can affix the switch to a flat surface using the two threaded screw holes on the bottom of the chassis. The holes use M4 screws (not provided) and are 100 millimeters (3.94 inches) apart. 3.
AT-FS705E FC and AT-FS706E FC Installation Guide The AT-FS705E FC switch has one 100FX DUPLEX switch for its one fiber optic port. The AT-FS706E FC switch has two switches for its two fiber optic ports. 7. Power ON the end nodes connected to the ports on the switch. 8. Check the LNK/ACTY LED for each port. The LED should be steady green or blinking. If a LNK/ACTY LED remains OFF, refer to “Verifying and Troubleshooting the Installation” on page 22 for assistance.
Note To prevent the DC power cable from being inadvertently pulled out of the switch, use the cable tie supplied with the unit to secure the DC power cable to the small cable hook located next to the DC connector. 6. Connect the twisted pair cables to the RJ45 connectors on the switch. 7. Remove the dust cover from the fiber optic port and connect the fiber optic cable to the port. 8. Set the 100FX DUPLEX switch to either HALF for half-duplex or FULL for full-duplex operation.
AT-FS705E FC and AT-FS706E FC Installation Guide Verify that the LNK/ACTY LED for each twisted pair port is either on or blinking. If an LED is off, do the following: G G G Verify that the end node connected to the port is powered ON and is operating properly. Check that the twisted pair cable is securely connected to the port on the switch and to the port on the end node. Make sure that the twisted pair cable does not exceed 100 meters (328 feet).
Warranty Registration When you have finished installing the switch, you should register your product by completing the enclosed warranty card and sending it in, or by visiting our web site at www.alliedtelesyn.com/forms/warranty.htm and completing the on-line registration. Technical Specifications Table 6 lists the switch specifications. Table 2 Technical Specifications Physical Specifications Dimensions (H x W x D) 1.7 cm x 17.9 cm x 9.8 cm (0.7 in x 7 in x 3.9 in) Weight 0.42 kg (0.
AT-FS705E FC and AT-FS706E FC Installation Guide Table 2 Technical Specifications (continued) Launch Power (dBm) Using 50/125 µm fiber: Max.: -14.0 Min.: -22.5 Avg.: -20.3 Using 62.5/125 µm fiber Max.: -14.0 Min.: -19.5 Avg.: -16.8 Receiver Power Using 50/125 µm fiber or 62.5/125 µm fiber: Max.: -31.8 Min.: -14.0 Avg.: -34.
Appendix A Translated Electrical Safety Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AT-FS705E FC and AT-FS706E FC Installation Guide Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. 1 Hochfrequenzstörung 2 WARNUNG: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
30 8 FARE UNDER UVEJR FARE: UNDLAD at arbejde på udstyr eller KABLER i perioder med LYNAKTIVITET. 9 ADVARSEL: DEN STRØMFØRENDE LEDNING BRUGES TIL AT AFBRYDE STRØMMEN. SKAL STRØMMEN TIL APPARATET AFBRYDES, tages ledningen ud af stikket. 10 UDSTYR TIL STIKKONTAKT, stikkontakten bør installeres nær ved udstyret og skal være lettilgængelig. 11 ADVARSEL: Ventilationsåbninger må ikke blokeres og skal have fri adgang til den omgivende luft i rummet for afkøling.
AT-FS705E FC and AT-FS706E FC Installation Guide Normes: ce produit est conforme aux normes de suivantes: 1 Emission d’interférences radioélectriques 2 MISE EN GARDE : dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates. 3 Immunité EN55024 4 Sécurité électrique UL 1950 (UL/cUL), EN60950 (TUV), EN60825 5 ATTENTION Producit laser di classe 1.
32 7 SÄHKÖÖN LIITTYVIÄ HUOMAUTUKSIA VAROITUS: SÄHKÖISKUVAARA Estääksesi SÄHKÖISKUN älä poista kantta. Sisällä ei ole käyttäjän huollettavissa olevia osia. Tämä laite sisältää VAARALLISIA JÄNNITTEITÄ ja sen voi avata vain koulutettu ja pätevä teknikko. Välttääksesi SÄHKÖISKUN mahdollisuuden katkaise sähkövirta tuotteeseen ennen kuin liität tai irrotat paikallisverkon (LAN) kaapelit.
AT-FS705E FC and AT-FS706E FC Installation Guide 12 TEMPERATURA DI FUNZIONAMENTO: Questo prodotto è concepito per una temperatura ambientale massima di 40 gradi centigradi. 13 TUTTI I PAESI: installare il prodotto in conformità delle vigenti normative elettriche nazionali. Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
34 7 AVISOS SOBRE CARACTERÍSTICAS ELÉTRICAS ATENÇÃO: PERIGO DE CHOQUE ELÉTRICO Para evitar CHOQUE ELÉTRICO, não retire a tampa. Não contém peças que possam ser consertadas pelo usuário. Este aparelho contém VOLTAGENS PERIGOSAS e só deve ser aberto por um técnico qualificado e treinado. Para evitar a possibilidade de CHOQUE ELÉTRICO, desconecte o aparelho da fonte de energia elétrica antes de conectar e desconectar os cabos da LAN.
AT-FS705E FC and AT-FS706E FC Installation Guide 12 TEMPERATURA REQUERIDA PARA LA OPERACIÓN: Este producto está diseñado para una temperatura ambiental máxima de 40 grados C. 13 PARA TODOS LOS PAÍSES: Monte el producto de acuerdo con los Códigos Eléctricos locales y nacionales. Standarder: Denna produkt uppfyller följande standarder.
Appendix B Technical Support Fax Order Name _________________________________________________________________ Company ______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province_______________________________ Zip/Postal Code ________________ Country_______________________________ Phone ______________________________ Fax________________________________ Incident Summary Model number of Allie
Appendix C AT-FS705E FC and AT-FS706E FC Installation Guide Feedback Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.