Installation guide

AT-FH705E Installation Guide
7
Problem 3:
Port 1 does not operate properly.
Solution 3:
The Uplink slide switch may be in the wrong position. Check the following:
When using the cascade port of the hub (Port 1), you should set the slide
switch to the
8SOLQNý
position.
When cascading two hubs, the unit using the cascade port should have
the button set to the
8SOLQN
position, while the other unit should have its
switch set
WRý1RGH
.
When port 1 is used to connect to a workstation or other equipment, you
should set the slide switch to the
ý1RGH
position.
Problem 4:
There is data loss between the hub and one of the attached network nodes.
Solution 4:
Make sure that the cable length between the hub and the connected
network device is no greater than 100 m (328 ft).
Make sure you are using Category 5 cable.