System information
Note - Valid MIB Set values for the Default Port parameter are in the range
[1024-2147483647] inclusive. Attempting to set this parameter to a value
outside the valid range will not result in an error but the new value will not
be applied.
Note - When setting the Profile parameter to 'none', the current firmware is
able to set the parameter successfully for the CLI but not for SNMP. As a
result, Device Manager will continue to display the old value.
Note - The current firmware version does not allow the user to enter
multiple-word values for the NAT IP Address and Interface parameters.
Attempting to do so will result in the error message: "The error occurred
with 'Set' operation. Error: commit Failed."
Note - Valid MIB Set values for the Max Retransmit Time parameter are in
the range [11-86400] inclusive. However, when the Roundtrip Time
parameter is set to its minimum value of 500, the current firmware version
allows the Max Retransmit Time parameter to be set to a value less than 11.
Note - AT-RG634A: Valid MIB Set values for the Interface parameter are in
the range [1-75] inclusive. But the current firmware version allows the
parameter to be set to more than 75 characters.
Note - AT-RG634A: Valid MIB Set values for the NAT IP Address parameter
are in the range [0-255] inclusive. Attempting to set this parameter to a value
outside the valid range will result in the error message: "No access error."
Note - AT-RG634A: Values displayed on the Protocol Info MIB variable
window may not be consistent with what is set on the device.
Note - AT-RG634A: Valid MIB Set values for the Interface parameter is in the
range [1-75] inclusive. Attempting to set this parameter to a value outside
the valid range will not result to an error message but will cause the device
to restart.
Note - AT-RG644B: The current firmware version accepts anywhere from 1
to 67 characters inclusive for the Interface parameter. Attempting to enter a
string value whose length is outside of the valid range will cause the device to
restart and will eventually result in the error message: "The error occurred
with 'Set' operation. Error: time out occurred."
Call Agent Info
Displays a list of all call agents available.
Note - AT-RG634A: It may take a while before the correct number of call
agents are displayed in Device Manager.
AlliedViewâ„¢-EMS 3.8 DEVICE MANAGEMENT GUIDE Page 301 of 330