Specifications
Hardware Reference 5
C613-03084-00 REV A
Environmental conditions
• Operating temperature range: 0º C to 50º C (32º F to 122º F)
• Storage temperature range: -25º C to 70º C (-13º F to 158º F)
• Operating humidity range: 5% to 80% non-condensing
• Storage humidity range: 5% to 95% non-condensing
• Operational altitude: 3,050 metres maximum (10,000 feet)
Regulatory standards
• EMC: EN55022 class A, FCC class A, and VCCI class A. EN61000-3
levels 2 (Harmonics), and 3 (Flicker) (AC models only)
• Immunity testing to EN55024
• Safety: UL60950-1, CAN/CSA-C22.2 NO. 60950-1-03, EN60950-1,
AS/NZS60950, EN60825-1
• Certification: UL, cUL, TUV
LEDs
• Port, System, and power supply unit status LEDs
• A complete list of LEDs and their functions is described in “LEDs and
What They Mean” on page 23
Power supply units
• Power supply units (PSUs) are hot-swappable and load share
• AC or DC PSU options
Dimensions:
•Height: 40.9 mm
• Width: 193 mm
• Depth: 130 mm
AC models
• Universal 100/240 VAC 47/63 Hz input
• Maximum continuous current draw, 2.2 A at 100 V, 1.1 A at 230 V
• Maximum inrush current (cold start at 25º C/77º F), 70 A at 240 V, 32 A
at 115 V
Important information for service personnel:
CAUTION: double pole/neutral fusing
The rating of fuses FH101 and FH102 is 250 V, 5 A
DC models
• 40 V to 60 V, 48 V nominal
• Supports either positive grounded or negative grounded operation
• Maximum continuous current draw, 3.9 A at 40 V
• Maximum standby current, 100 mA
•Run/Standby switch