- Allied Telesis, Inc Switches Datasheet
Features in 276-02 24
Version 276-03
C613-10474-00 REV B
CR00011995
BGP 4 To simplify displaying BGP memory usage, the command show bgp memlimit
bgp has been removed. Use the command show bgp memlimit scan instead.
Also, you can now display only the BGP backoff log messages by using either of
the following commands:
show log type=55 subtype=backoff
show log type=55 subtype=7
YYYYY- - YYY
CR00012043
BGP 4 When a user entered conflicting values for BGP backoff thresholds (the backoff
and low parameters of the set bgp backoff command), the error message did
not adequately show the dependency between these two parameters.
This issue has been resolved. The error message now reads (for example):
Error (3103332): BACKOFF parameter value 90 too low; must be greater than
LOW parameter value 94.
YYYYY- - YYY