- Allied Telesis, Inc Switches Datasheet

Features in 276-02 23
Version 276-03
C613-10474-00 REV B
Level 4
CR00012594
STT 3 With unidirectional traffic or small frames, an STT connection would sometimes
stop passing data.
This issue has been resolved.
YYYY------
CR Module Level Description
AR44x / AR450
AR7x5
AR750S
Rapier i
AT-8800
AT-8600
AT-8700XL
AT-8948
AT-9900
AT-9800
CR00003286
Core, ISDN 4 Previously, the log message generated when an ISDN call came up sometimes
reported the channel as “channel unknown” when the channel was encoded as
a channel map instead of a channel number. The type of encoding depends on
the local ISDN provider, so this issue only occurred in some parts of the world.
This issue has been resolved. When the channel has been encoded as a channel
map, the log message now displays one of the following:
a channel number if only one channel is encoded (the most common case), or
the entire channel map in decimal format if more than one channel is
encoded, for example:
28 11:51:21 3 ICC CALL UP ISDN call ACTIVE, direction IN , channel map 12.
YYYY------
CR Module Level Description
AR44x / AR450
AR7x5
AR750S
Rapier i
AT-8800
AT-8600
AT-8700XL
AT-8948
AT-9900
AT-9800