Specifications

36 AT-9800 Series Switch
C613-03059-00 REV F
The following figure is an example of output from the show system command
for an AT-9800 Series switch.
The Memory field displays the size of DRAM. If the DRAM size is less than the
size of DIMM that has been installed, then the switch has not correctly detected
the DIMM. The most likely cause is that the DIMM connector is not plugged
into its slot correctly. Repeat the installation process, paying particular
attention to the DIMM insertion step.
Use the show system command again, and if the display is still not correct,
contact your authorised Allied Telesis distributor or reseller.
Important If you have any difficulty with the DIMM at any time, contact your
authorised Allied Telesis distributor or reseller and quote the serial numbers of
both the base card on the switch and the DIMM. The switch’s serial numbers
and revision details can be read using the show system command. It’s a good
idea to record this information for later reference.
Switch System Status Time 11:25:50 Date 28-Mar-2002.
Board ID Bay Board Name Rev Serial number
--------------------------------------------------------------------------------
Base 156 AT-9816GF M1-1 46709354
--------------------------------------------------------------------------------
Memory - DRAM : 65536 kB FLASH : 15360 kB
--------------------------------------------------------------------------------
SysDescription
Allied Telesis AT-9816GF version 2.5.1-00 10-Nov-2002
SysContact
SysLocation
SysName
SysDistName
SysUpTime
3382 ( 00:00:33 )
Boot Image : 98-101.fbr size 903404 20-Aug-2002
Software Version: 2.5.1-00 10-Nov-2002
Release Version : 2.5.1-00 10-Nov-2002
Release built : Nov 10 2002 at 00:20:31
Patch Installed : NONE
Territory : usa
Help File : help.hlp
Main PSU : On Main Fan : On
RPS Monitor : On RPS Connected : ***NO***
Current Temperature : 29 C
Configuration
Boot configuration file: snoopy.cfg (exists)
Current configuration: snoopy.cfg
Security Mode : Disabled
Warning (2048283): No patches found.