Specifications
Hardware Reference 33
C613-03059-00 REV F
Testing CAM
To check that the switch has recognised the CAM, turn on the switch and enter
the command:
show switch
This displays system system information, including the amount of CAM
installed. The following figure is an example of output from the show switch
command.
If there is no entry for the CAM, or the entry displays an incorrect value, then
the switch has not correctly detected the CAM’s presence. The most likely
cause is that the CAM is not correctly plugged into the CAM slot. Repeat the
installation process, paying particular attention to the CAM alignment and
insertion steps.
Use the show switch command again, and if the display is still not correct,
contact your authorised Allied Telesis distributor or reseller.
Important If any CAM test fails, check that the CAM is correctly installed in its
slot and repeat the tests. Contact your authorised Allied Telesis distributor or
reseller if the CAM does not operate correctly.
Switch Configuration
------------------------------------------------------------
CAM size ( entries ) ....... 204800
Switch Address ............. 00-00-cd-05-01-0f
Learning ................... ON
Ageing Timer ............... ON
Number of Fixed Ports ...... 16
Number of Uplink Ports ..... 0
Mirroring .................. DISABLED
Mirror port ................ None
Ports mirroring on Rx ...... None
Ports mirroring on Tx ...... None
Ports mirroring on Both .... None
Number of WAN Interfaces ... 0
Name of Interface(s) ....... -
Ageingtime ................. 300
VLAN classification ........ To be defined
UpTime ..................... 00:01:21
Hashingfiled ............... L2 L3 L4
-----------------------------------------------------------