AT-9800 Series Switch Quick Install Guide AT-9812T V2 AT-9816GB V2
AT-9800 Series Switch Quick Install Guide Document Number C613-04038-01 REV H. © 2003-2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis, Inc. reserves the right to make changes in specifications and other information in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc.
Quick Install Guide 3 Models Covered By This Guide This Quick Install Guide includes information on the following models: ■ AT-9812T V2 ■ AT-9816GB V2 Package Contents The following items are included with each AT-9800 Series switch. Contact your sales representative if any items are damaged or missing.
AT-9800 Series Switch Installing the Switch This equipment must be earthed. Follow these steps to install the switch: 1. Read the safety information For safety information, see the AT-9800 Series Safety and Statutory Information booklet. A copy of this booklet is supplied with each switch, and can also be found on the Documentation and Tools CD-ROM or at www.alliedtelesis.com/support/software. 2.
Quick Install Guide 5 Figure 1: AT-9816GB front panel and rear panel with AC power inlet AT-9816GB V2 Layer 3 Fast Ethernet Switch 1000BASE-X GBIC PORT ACTIVITY L/A GBIC L/A 1 2 3 4 5 6 7 LINK / FULL DUP ACTIVITY LINK / HALF DUP ACTIVITY ENABLED DISABLED FAULT 8 1 2 3 4 5 6 7 RS-232 TERMINAL PORT STATUS ASYN0 FAULT 8 L/A GBIC RPS L/A PWR GBIC 9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 RESET 16 COMPACT FLASH AC INPUT HZ AMPS 100-240V 50/60 5.0/2.
AT-9800 Series Switch d) Ensure that there are no exposed conductor strands. e) Secure the supply cable to the rack framework or similar object so that the connections are isolated from any forces applied to the cable. f) Ensure that the circuit breaker is in the OFF position. g) Connect the supply cable wires to the circuit breaker. h) Energise the circuit breaker. The Fault LED should flash for approximately 10 seconds as the switch runs internal tests.
Quick Install Guide 7 Configuring the Switch Some configuration is necessary to enable the advanced switching capabilities of the switch. The switch can be configured via the Command Line Interface (CLI) or Graphical User Interface (GUI). Using the CLI to configure a switch 1. Connect a terminal or PC to RS-232 (ASYN0) Using the supplied RS-232 DB9 straight-through cable, connect your terminal or PC to the RS-232 Terminal Port on the switch’s front panel. 2.
AT-9800 Series Switch Alternatively, type a question mark (?) at the end of a partially completed command to see a list of valid options. See the AT-9800 Series Switch AlliedWare™ Operating System Software Reference for more information on configuring the switch. Using the GUI to configure a switch This section describes how to establish a connection to the switch through the GUI, so you can configure the switch before installing it in your LAN. 1.
Quick Install Guide 9 System LEDs The following LEDs report operations and faults on AT-9800 Series switches (Table 1).
AT-9800 Series Switch Documentation and Tools CD-ROM The Documentation and Tools CD-ROM bundled with each switch contains the complete Documentation Set for AT-9800 Series switches and their expansion options, as well as tools for managing the Switch. The CD-ROM includes: ■ The AT-9800 Series Statutory and Safety Information booklet, which provides safety and statutory information for the Switch and its expansion options.