Specifications

4 AT-9800 Series Switch
C613-03059-00 REV E
Dimensions
Height = 66 mm (plus 5.5 mm if the rubber feet are used)
Width = 440 mm (excluding rack-mounting brackets)
Depth = 360 mm
Weight = Not more than 6.6 kg, depending on model (excluding power
cord)
Mounting System
1.5U rack mounting
Environmental Conditions
Operating temperature range: 0 to 40º C (32 to 104º F)
Storage temperature range: -25 to 70º C (-13 to 158º F)
Relative humidity range: 5 to 95% non-condensing
LEDs
Port and System status LEDs
For a complete list of LEDs and their functions, see LEDs and What
They Mean” on page 26.
Power Supply Unit
AC models
Universal 100/240 VAC 50/60 Hz input
Redundant DC Power connection
DC models
48 VDC (40-60 VDC is acceptable)
Accepts positive or negative earthing (grounding)
Maximum Current Loads
AC models
Maximum continuous current draw, 2.2A at 220V, 4.3A at 110V
Maximum inrush current (cold start at 25º C/77º F), 60A at 220V, 30A at
110V
DC models
Maximum continuous current draw, 4.0A at -40V
Switching Core
Application-Specific Integrated Circuit (ASIC) switch chip
Non-blocking L2 and L3 IP Switching
40 k-entry forwarding address database (expandable to 232 k-entries
with LineCAM)
64 MByte RAMBUS packet buffer