Specifications
Hardware Reference 41
C613-03059-00 REV E
totally dedicated to their use. A detailed knowledge of the way the switch
hardware functions is necessary if diagnostics are to be used effectively.
The switch will not perform switching operations if diagnostics are running.
This section is not intended as a guide to the diagnostics software. Diagnostics
are designed to be run by service personnel only. For more information, contact
your Authorised Allied Telesyn distributor or reseller.
To enable diagnostics mode:
1. Connect a terminal to the RS-232 Terminal Port (ASYN0).
Using a terminal cable, connect a terminal to the RS-232 Port (ASYN0) on
the switch. See “Useful Cables” on page 16 for more information on
terminal cables.
Set the terminal communication parameters to the following:
• Baud rate: 9600
• Data bits: 8
•Parity: None
• Stop bits: 1
• Flow control: Hardware
2. Restart the switch.
Restart the switch, either by using a pen or pencil to operate the recessed
reset button on the switch’s front panel, or by using the terminal to log in
and enter the command:
RESTART REBOOT
See “To log In” on page 11 for more information on how to log in.
3. Enable diagnostics mode during start-up.
During the switch start-up process, at the prompt:
Force EPROM download (Y)?
press [Ctrl/D] on the terminal to enter diagnostics mode. A banner page will
be displayed on the terminal (Figure 20 on page 42). This can be used to
check that the terminal is correctly connected.
Performing a Full flash Test or erasing flash will delete all configuration and
release files. Make sure you know how to reload these files before erasing flash
or performing a flash test.