Specifications
40 AT-9800 Series Switch
C613-03059-00 REV E
After repeating the installation, use the SHOW SYSTEM command again, and
if the display is still not correct, contact your authorised Allied Telesyn
distributor or reseller.
If you have any difficulty with the DIMM at any time, contact your authorised Allied
Telesyn distributor or reseller and quote the serial numbers of both the base card on the
switch and the DIMM. The switchâs serial numbers and revision details can be read
using the SHOW SYSTEM command. Itâs a good idea to record this information for
later reference.
Figure 19: Example output from the SHOW SYSTEM command for an AT-9800 Series switch, showing DRAM.
Diagnostics
The switch software includes a set of diagnostic programs. These programs
perform basic level checks of all system components. They do not run in
conjunction with the normal operating code, and require that the system be
Switch System Status Time 11:25:50 Date 28-Mar-2002.
Board ID Bay Board Name Rev Serial number
--------------------------------------------------------------------------------
Base 156 AT-9816GF M1-1 46709354
--------------------------------------------------------------------------------
Memory - DRAM : 65536 kB FLASH : 15360 kB
--------------------------------------------------------------------------------
SysDescription
Allied Telesyn AT-9816GF version 2.5.1-00 10-Nov-2002
SysContact
SysLocation
SysName
SysDistName
SysUpTime
3382 ( 00:00:33 )
Boot Image : 98-101.fbr size 903404 20-Aug-2002
Software Version: 2.5.1-00 10-Nov-2002
Release Version : 2.5.1-00 10-Nov-2002
Release built : Nov 10 2002 at 00:20:31
Patch Installed : NONE
Territory : usa
Help File : help.hlp
Main PSU : On Main Fan : On
RPS Monitor : On RPS Connected : ***NO***
Current Temperature : 29 C
Configuration
Boot configuration file: snoopy.cfg (exists)
Current configuration: snoopy.cfg
Security Mode : Disabled
Warning (2048283): No patches found.