Specifications
Features in 291-08 82
Version 291-18
C613-10488-00 REV Q
CR00017337 Switching 2 It was possible to set up a classifier that matched MPLS frames at layer 2,
but the switch would not correctly match these MPLS frames against the
classifier.
This issue has been resolved. The switch now correctly matches MPLS
frames against such a classifier.
--------YY-
CR00017368 QoS,
DHCP
Snooping
2 Some small memory access violations existed in DHCP snooping.
These violations have been resolved.
Also, a new console error message is displayed if a user tries to add a
duplicate classifier to a QoS policy. For example, if traffic class 101 belongs
to policy 2 and a user tries to add a flow group to traffic class 101 when
the flow group’s classifier is number 54 and already belongs to policy 2, the
following message is displayed:
Error (3099297): Duplicate classifier (54) on policy 2.
A similar new log message has also been added, which says:
Duplicate classifier (<number>) found on <string> <number>
Note that a classifier can exist in two separate policies but cannot exist
twice in the same policy.
- - - YYYYYYY-
CR00017456 IP Gateway 2 The router or switch could reboot when the local interface address had
been specified by using the set ip local command, and then the underlying
interface from which the local interface took its address was either deleted
or had its address changed. In both these cases, the local interface was
correctly reset back to an undefined address, but a route to this address was
not deleted. This could cause routing difficulties and a reboot when packets
for that address were received.
This issue has been resolved. The route is now correctly deleted.
YYYYYYYYYYY
CR Module Level Description
AR400
AR7x5
AR7x0S
Rapier i
Rapier w
AT-8800
AT-8600
AT-8700XL
x900-48
AT- 9900
AT-9800