Specifications
Features in 291-11 63
Version 291-18
C613-10488-00 REV Q
CR00013774 Switch, MSTP 4 If MSTP was enabled and a port was set as the mirror port, it was possible
for the switch to send BPDUs out of this port. Note these BPDUs were
originated by the switch, not mirrored from another port.
This issue has been resolved.
–––YYYYYYY–
CR00013916 Switch 4 For the ingresslimit and egresslimit parameters of the set switch port
command, the output of the “?” help previously said that the range of
values was 0 to 4294967295.
This issue has been resolved. The “?” help output now gives the correct
ranges, which are:
■ 1000 to 127000 (in kbps) for 10/100 Mbps ports
■ 8 to 1016 (in Mbps) for 1 Gbps ports
–––YYYYY–––
CR00015655 User, RADIUS 4 Previously, the router or switch did not log a message if RADIUS
authenticated a user logging in over telnet but RSO rejected the login.
This issue has been resolved. A message is now logged, with module USER,
type RSO, and subtype RJCT. The message reads “Remote Security Officer
access rejected from user <name> at <ip-address>.”
YYYYYYYYYYY
CR00017449 Switch 4 The set switch port speed command incorrectly accepted a value of
1000mhalf for tri-speed copper SFP ports.
This issue has been resolved. If you enter 1000mhalf, the switch displays
an error.
–––––––––Y–
CR00017971 Utility 4 The “?” help for some parameter options (including add igmp filter=id
group=address action=?) did not show all the available options.
This issue has been resolved.