Specifications

Features in 291-13 38
Version 291-18
C613-10488-00 REV Q
Features in 291-13
Software Maintenance Version 291-13 includes the resolved issues and enhancements in the following tables. In the tables, for each product series:
“Y” indicates that the resolution is available in Version 291-13 for that product series.
” indicates that the issue did not apply to that product series.
Level 1
No level 1 issues.
Level 2
CR Module Level Description
AR44x / AR450
AR7x5
AR750S / AR770S
Rapier i
Rapier w
AT-8800
AT-8600
AT-8700XL
AT-8948 / x900-48
AT-9900
AT-9800
CR00018575 L2TP 2 If an L2TP tunnel had a large number of PPP interfaces over it, and the link
that the L2TP tunnel was over went down, the router or switch might
restart. This issue has been resolved.
YYYYYY–YYY
CR00019285 SHDSL 2 The AR442S router’s SHDSL interface would not "train up" with some
Alcatel DSLAMs, because of an EOC message exchange issue.
This issue has been resolved. Some other issues with EOC message
reception were also resolved.
Y––––––––––
CR00020240 PIM 2 In PIM, if the RPF neighbour to the source or the RP changed as a result of
a unicast route change, and there were slow route updates, and that meant
a new route to the RPF could not be found within 5 seconds, then multicast
traffic would not resume correctly once the new routing information was
learned.
This issue has been resolved.