Specifications
Features in 291-04 142
Version 291-18
C613-10488-00 REV Q
CR00013589 Install 4 When a router or switch was using a trial licence for release software and the trial
period elapsed, the router or switch rebooted without indicating the reason for
the reboot.
This issue has been resolved. The following error messages now explain why the
router or switch is rebooting:
ERROR: There are no valid licences available for the current software release.
The device will now reboot.
ERROR: The trial licence for the current software release has expired.
The device will now reboot.
YYYYYYYYYY
CR00013640 NTP 4 Output of the command show ntp displays a “Host Address” field. This is the
address of the interface from which the router or switch sends NTP packets.
Previously, if the IP address changed, the “Host Address” field did not change,
even though NTP used the new address.
This issue has been resolved.
YYYYYYYYYY
CR00014106 Core 4 If the router or switch runs a configuration file on start-up that contains the
command set summertime before the command enable summertime, a log
message on start-up says that summertime needs to be enabled. However,
summertime is correctly applied to the router or switch.
Previously, if you configured summertime then saved the configuration by using
the command create config, set summertime came before enable
summertime in the resulting configuration file.
This issue has been resolved. When you save the configuration, enable
summertime now comes before set summertime in the resulting configuration
file, so the log message is not produced.
YYYYYYYYYY
CR00014151 VLAN 4 The following error message:
“Error (3089399): Operation not allowed on a .NESTED port.”
contained an extraneous “.” before the word “NESTED”.
This issue has been resolved. The “.” has been removed.
–––––––YY–
CR Module Level Description
AR400
AR7x5
AR7x0S
Rapier i
AT-8800
AT-8600
AT-8700XL
x900-48
AT- 9900
AT-9800